Larbanois, Alexandra
[UCL]
Delwiche, J-P
[UCL]
Jamart, Jacques
[UCL]
Vandenplas, Olivier
[UCL]
BACKGROUND: There is theoretical evidence that specific airway conductance (SGaw) could be more reliable than forced expiratory volume in 1 s (FEV1) for assessing changes in airway calibre. We investigated the changes in FEV1 and SGaw when assessing bronchial responses to occupational agents. METHODS: SGaw and FEV1 were measured during inhalation challenges with various occupational agents in 174 consecutive subjects investigated for possible occupational asthma. RESULTS: A decline in SGaw of 50% or greater was documented in 77 of 90 subjects (86%) who showed a >/=20% fall in FEV1 and in 11 of 84 subjects (13%) who failed to demonstrate such a fall in FEV1. Among subjects who developed a >/=20% fall in FEV1, those who failed to develop a >/=50% decline in SGaw had a lower baseline SGaw than those who did. Among the group without a >/=20% fall in FEV1, a >/=50% decrease in SGaw was associated with either an 'intermediate' fall in FEV1 (between 15 and 17% from baseline value) (n = 4), a significant postchallenge increase in nonspecific bronchial hyper-responsiveness to histamine (n = 2), or both features (n = 3). CONCLUSIONS: A decline in SGaw of 50% or greater may provide useful complementary evidence of a bronchial response during challenges that produce equivocal results in FEV1.
- Meredith, Thorax, 51, 435 (1996)
- Malo, J Allergy Clin Immunol, 108, 317 (2001)
- Pepys, Am Rev Respir Dis, 112, 829 (1975)
- Vandenplas, Eur Respir J, 10, 2612 (1997)
- Chan-Yeung, Chest, 108, 1084 (1995)
- Vandenplas, J Allergy Clin Immunol, 107, 542 (2001)
- Sterk P. J., Fabbri L. M., Quanjer P. H., Cockcroft D. W., O'Byrne P. M., Anderson S. D., Juniper E. F., Malo J.- L., Standardized challenge testing with pharmacological, physical and sensitizing stimuli in adults, 10.1183/09041950.053s1693
- Crapo, Am J Respir Crit Care Med, 161, 309 (2000)
- Orehek, Am Rev Respir Dis, 121, 297 (1980)
- Orehek, Am Rev Respir Dis, 123, 269 (1981)
- Cockcroft, Ann Allergy, 51, 374 (1983)
- Fish, J Allergy Clin Immunol, 64, 592 (1979)
- Dehaut, Thorax, 38, 516 (1983)
- Chan-Yeung, Am Rev Respir Dis, 108, 1103 (1973)
- Standardization of Spirometry, 1994 Update. American Thoracic Society., 10.1164/ajrccm.152.3.7663792
- European Community for Coal and Steel, Bull Europ Physiopath Resp, 19, 45 (1983)
- Cockcroft, Clin Allergy, 7, 235 (1977)
- Vandenplas, Thorax, 51, 472 (1996)
- Perrin, J Allergy Clin Immunol, 87, 630 (1991)
- Stenton, Eur Respir J, 7, 806 (1994)
- Sundblad, Clin Physiol, 21, 673 (2001)
- Macklem, J Appl Physiol, 22, 395 (1967)
- Bouhuys, J Clin Invest, 49, 106 (1970)
- Van Brabandt, J Appl Physiol, 55, 1733 (1983)
- Schmekel, Chest, 106, 1781 (1994)
Bibliographic reference |
Larbanois, Alexandra ; Delwiche, J-P ; Jamart, Jacques ; Vandenplas, Olivier. Comparison of FEV1 and specific airway conductance in assessing airway response to occupational agents.. In: Allergy, Vol. 58, no. 12, p. 1256-60 (2003) |
Permanent URL |
http://hdl.handle.net/2078.1/9663 |