Analysis of the accuracy of continuous thermodilution cardiac output measurement - Comparison with intermittent thermodilution and Fick cardiac output measurement

Bibliographic reference Jacquet, Luc-Marie ; Hanique, G. ; Glorieux, D ; Matte, P. ; Goenen, Martin. Analysis of the accuracy of continuous thermodilution cardiac output measurement - Comparison with intermittent thermodilution and Fick cardiac output measurement. In: Intensive Care Medicine, Vol. 22, no. 10, p. 1125-1129 (1996)
Permanent URL
  1. BERNSTEIN DONALD P., Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance : , 10.1097/00003246-198610000-00015
  2. Perrino AC, Lippman A, Ariyan C, O'Connor TZ, Luther M (1994) Intraoperative cardiac output monitoring: comparison of impedance cardiography and thermodilution. J Cardiothorac Vasc Anesth 8:24–29
  3. DAVIES. GERALD G., JEBSON PETER J. R., GLASGOW BRIAN M., HESS DOUGLAS R., Continuous Fick cardiac output compared to thermodilution cardiac output : , 10.1097/00003246-198610000-00010
  4. KEINANEN OLAVI, TAKALA JUKKA, KARI PHD; AARNO, Continuous measurement of cardiac output by the Fick principle : Clinical validation in intensive care, 10.1097/00003246-199203000-00012
  5. Jansen J. R. C., Wesseling K. H., Settels J. J., Schreuder J. J., Continuous cardiac output monitoring by pulse contour during cardiac surgery, 10.1093/eurheartj/11.suppl_i.26
  6. Abrams Jerome H., Weber Roland E., Holmen Kenneth D., Transtracheal Doppler : A New Procedure for Continuous Cardiac Output Measurement, 10.1097/00000542-198901000-00025
  7. Miyasaka Keiko, Takata Masao, Miyasaka Katsuyuki, Flow velocity profile of the pulmonary artery measured by the continuous cardiac output monitoring catheter, 10.1007/bf03011318
  8. Yelderman M, Ramsay MA, Quinn MD, Paulsen AW, McKown RC, Gillman PH (1992) Continuous thermodilution cardiac output measurement in intensive care unit patients. J Cardiothorac Vasc Anesth 3:270–274
  9. Boldt Joachim, Menges Thilo, Wollbrück Mathias, Hammermann Hans, Hempelmann Gunter, Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient? : , 10.1097/00003246-199422120-00005
  10. Yelderman Mark, Continuous measurement of cardiac output with the use of stochastic system identification techniques, 10.1007/bf02842492
  11. Mihaljevic T., Segesser L. K. von, Tönz M., Leskosek B., Jenni R., Turina M., Continuous Thermodilution Measurement of Cardiac Output: In-Vitro and In-Vivo Evaluation, 10.1055/s-2007-1016451
  12. Thrush David, Downs John B., Smith Robert A., Continuous thermodilution cardiac output: Agreement with fick and bolus thermodilution methods, 10.1016/s1053-0770(05)80094-1
  13. Jansen JRC, Versprille A (1986) Improvement of cardiac output estimation of the thermodilution method during mechanical ventilation. Intensive Care Med 12:71–79
  14. Stevens JH, Raffin TA, Mihm FG, Rosenthal MH, Stetz CW (1985) Thermodilution cardiac output measurement. Effects of the respiratory cycle on its reproducbility. JAMA 253:2240–2242
  15. TAKALA JUKKA, KEINÄNEN OLAVI, VÄISÄNEN PAULA, KARI AARNO, Measurement of gas exchange in intensive care : Laboratory and clinical validation of a new device, 10.1097/00003246-198910000-00015
  16. MAKITA KOSHI, NUNN JOHN F., ROYSTON BARBARA, Evaluation of metabolic measuring instruments for use in critically ill patients : , 10.1097/00003246-199006000-00013
  18. Yelderman M, Quinn MD, McKnown RC, Eberhart RC, Dollar ML (1992) Continuous thermodilution cardiac output measurement in sheep. J Thorac Cardiovasc Surg 104:315–320
  19. Lichtenthal P. R., Marchand B., Gordon D., Leissing N., Konno M., A Safety Comparison Between A New Continuous Cardiac Output (CCO) Monitoring System And A Standard Pulmonary Artery Catheter In Sheep : , 10.1097/00000542-199209001-00473