A quality control system especially designed for dosimetry in scanning proton beams has been designed and tested. The system consists of a scintillating screen (Gd2O2S:Tb), mounted at the beam-exit side of a phantom, and observed by a low noise CCD camera with a long integration time. The purpose of the instrument is to make a fast and accurate two-dimensional image of the dose distribution at the screen position in the phantom. The linearity of the signal with the dose, the noise in the signal, the influence of the ionization density on the signal, and the influence of the field size on the signal have been investigated. The spatial resolution is 1.3 mm (1 s.d.), which is sufficiently smaller than typical penumbras in dose distributions, The measured yield depends linearly on the dose and agrees within 5% with the calculations. In the images a signal to noise ration (signal/l s.d.) of 10(2) has been found, which is in the same order of magnitude as expected from the calculations. At locations in the dose distribution possessing a strong contribution of high ionization densities (i.e., in the Bragg peak), we found some quenching of the light output, which can be described well by existing models if the beam characteristics are known. For clinically used beam characteristics such as a Spread Out Bragg peak, there is at most 8% deviation from the NACP ionization chamber measurements. The conclusion is that this instrument is a useful tool for quick and reliable quality control of proton beams. The long integration-time capabilities of the system make it worthwhile to investigate its applicability in scanning proton beams and other dynamic treatment modalities. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)02104-X].
Boyer Arthur L., Antonuk Larry, Fenster Aaron, Van Herk Marcel, Meertens Harm, Munro Peter, Reinstein Larry E., Wong John, A review of electronic portal imaging devices (EPIDs) : Review Article: Review of electronic portal imaging devices, 10.1118/1.596878
Maryanski Marek J., Gore John C., Kennan Richard P., Schulz Robert J., NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: A new approach to 3D dosimetry by MRI, 10.1016/0730-725x(93)90030-h
Olsson L E, Fransson A, Ericsson A, Mattsson S, MR imaging of absorbed dose distributions for radiotherapy using ferrous sulphate gels, 10.1088/0031-9155/35/12/003
Munro P., Rawlinson J.A., Fenster A., A digital fluoroscopic imaging device for radiotherapy localization, 10.1016/0360-3016(90)90073-s
Kirby M.C., Williams P.C., Measurement possibilities using an electronic portal imaging device, 10.1016/0167-8140(93)90253-5
Kirby Michael C., Williams Peter C., The use of an electronic portal imaging device for exit dosimetry and quality control measurements, 10.1016/0360-3016(94)00388-2
Essers Marion, Boellaard Ronald, van Herk Marcel, Lanson Hugo, Mijnheer Ben, Transmission dosimetry with a liquid-filled electronic portal imaging device, 10.1016/0360-3016(95)02191-4
Boellaard Ronald, van Herk Marcel, Uiterwaal Hans, Mijnheer Ben, Two-dimensional exit dosimetry using a liquid-filled electronic portal imaging device and a convolution model, 10.1016/s0167-8140(97)00073-x
23
Leong J, Use of digital fluoroscopy as an online verification device in radiation therapy, 10.1088/0031-9155/31/9/004
Wong John W, Cheng Abel Y, Binns W.Robert, Epstein John W, Klarmann Joseph, Perez Carlos A, Development of a second-generation fiber-optic on-line image verification system, 10.1016/0360-3016(93)90212-e
Perera Harold, Williamson Jeffrey F., Monthofer Suzanne P., Binns Walter R., Klarmann Joseph, Fuller Gary L., Wong John W., Rapid two-dimensional dose measurement in brachytherapy using plastic scintillator sheet: linearity, signal-to-noise ratio, and energy response characteristics, 10.1016/0360-3016(92)90914-4
Radiation Dosimetry
Michaelian K., Menchaca-Rocha A., Model of ion-induced luminescence based on energy deposition by secondary electrons, 10.1103/physrevb.49.15550
Badhwar G.D., Deney C.L., Dennis B.R., Kaplon M.F., The non-linear response of the plastic scintillator NE102, 10.1016/0029-554x(67)90507-1
Craun R.L., Smith D.L., Analysis of response data for several organic scintillators, 10.1016/0029-554x(70)90768-8
Avdeichikov V.V., Bergholt L., Guttormsen M., Taylor J.E., Westerberg L., Jakobsson B., Klamra W., Murin Yu.A., Light output and energy resolution of CsI, YAG, GSO, BGO and LSO scintillators for light ions, 10.1016/0168-9002(94)90623-8
Murray R. B., Meyer A., Scintillation Response of Activated Inorganic Crystals to Various Charged Particles, 10.1103/physrev.122.815
Maier K.H., Nitschke J., Die lichtausbeute eines NE 213-szintillators für protonen, 10.1016/0029-554x(68)90502-8
Fomichev A.S., David I., Lukyanov S.M., Penionzhkevich Yu.E., Skobelev N.K., Tarasov O.B., Matthies A., Ortlepp H.-G., Wagner W., Lewitowicz M., Saint-Laurent M.G., Corre J.M., Dlouhý Z., Pecina I., Borcea C., The response of a large CsI(Tl) detector to light particles and heavy ions in the intermediate energy range, 10.1016/0168-9002(94)90086-8
Meyer Axel, Murray R. B., Effect of Energetic Secondary Electrons on the Scintillation Process in Alkali Halide Crystals, 10.1103/physrev.128.98
Althof V. G. M., de Boer J. C. J., Huizenga H., Stroom J. C., Visser A. G., Swanenburg B. N., Physical characteristics of a commercial electronic portal imaging device, 10.1118/1.597836
Munro P., Rawlinson J. A., Fenster A., Therapy imaging: A signal-to-noise analysis of a fluoroscopic imaging system for radiotherapy localization : Analysis of a fluoroscopic imaging system, 10.1118/1.596474
Radcliffe T., Barnea G., Wowk B., Rajapakshe R., Shalev S., Monte Carlo optimization of metal/phosphor screens at megavoltage energies, 10.1118/1.596970
Buchanan, IEEE Trans. Nucl. Sci., NS-19, 3 (1972)
Techniques for Nuclear and Particle Physics Experiments
SCINT 95: Proceedings of the International Conference on Inorganic Scintillators and Their Applications
Giakoumakis G E, Miliotis D M, Light angular distribution of fluorescent screens excited by x-rays, 10.1088/0031-9155/30/1/003
Heijmen B J M, Pasma K L, Kroonwijk M, Althof V G M, Boer J C J de, Visser A G, Huizenga H, Portal dose measurement in radiotherapy using an electronic portal imaging device (EPID), 10.1088/0031-9155/40/11/012
Meertens H, Herk M van, Weeda J, An inverse filter for digital restoration of portal images, 10.1088/0031-9155/33/6/003
Introduction to Probability Models
Grusell E, Montelius A, Brahme A, Rikner G, Russell K, A general solution to charged particle beam flattening using an optimized dual-scattering-foil technique, with application to proton therapy beams, 10.1088/0031-9155/39/12/005
Chu W. T., Ludewigt B. A., Renner T. R., Instrumentation for treatment of cancer using proton and light‐ion beams, 10.1063/1.1143946
Experimental Nuclear Physics
Wambersie, Radiother. Oncol., 9, 33 (1987)
Bibliographic reference
Boon, SN ; van Luijk, P ; Schippers, JM ; Meertens, H ; Denis, JM. ; et. al. Fast 2D phantom dosimetry for scanning proton beams. In: Medical Physics, Vol. 25, no. 4, p. 464-475 (1998)