User menu

Response to the Letter to the Editor "Estimating RBEs at clinical doses from microdosimetric spectra"

Bibliographic reference Pihet, P. ; Menzel, HG.. Response to the Letter to the Editor "Estimating RBEs at clinical doses from microdosimetric spectra". In: Medical Physics, Vol. 26, no. 5, p. 848-852 (1999)
Permanent URL
  1. Brenner David J., Zaider Marco, Estimating RBEs at clinical doses from microdosimetric spectra, 10.1118/1.598278
  2. Schmidt R., Hess A., Microdosimetric Investigations for Neutron Therapy, 10.1093/oxfordjournals.rpd.a080204
  3. Pihet, Radiat. Prot. Dosim., 31, 437 (1990)
  4. Zaider M., Brenner D. J., On the Microdosimetric Definition of Quality Factors, 10.2307/3576753
  5. Low Dose Radiation: Biological Basis of Risk Assessment
  6. Menzel H.G., Pihet P., Wambersie A., Microdosimetric Specification of Radiation Quality in Neutron Radiation Therapy, 10.1080/09553009014550991
  7. Loncol T., Cosgrove V., Denis J.M., Gueulette J., Mazal A., Menzel H.G., Pihet P., Sabattier R., Radiobiological Effectiveness of Radiation Beams with Broad LET Spectra: Microdosimetric Analysis Using Biological Weighting Functions, 10.1093/rpd/52.1-4.347
  8. Tilikidis A, Lind B, Näfstadius P, Brahme A, An estimation of the relative biological effectiveness of 50 MV bremsstrahlung beams by microdosimetric techniques, 10.1088/0031-9155/41/1/005
  9. Paganetti Harald, Olko Pawel, Kobus Hubert, Becker Regina, Schmitz Thomas, Waligorski Michael P.R., Filges Detlef, Müller-Gärtner Hans-Wilhelm, Calculation of relative biological effectiveness for proton beams using biological weighting functions, 10.1016/s0360-3016(96)00540-8
  10. Coutrakon G., Cortese J., Ghebremedhin A., Hubbard J., Johanning J., Koss P., Maudsley G., Slater C. R., Zuccarelli C., Robertson J., Microdosimetry spectra of the Loma Linda proton beam and relative biological effectiveness comparisons, 10.1118/1.598038
  11. Kellerer, Curr. Top. Radiat. Res. Q., 8, 85 (1972)
  12. The Dosimetry of Ionizing Radiation, Vol. II
  13. Proc. 8th International Congress of Radiation Research, Edinburgh, July 1987
  14. The Dosimetry of Ionizing Radiation, Vol. I,
  15. Morstin K., Bond V. P., Baum J. W., Probabilistic Approach to Obtain Hit-Size Effectiveness Functions Which Relate Microdosimetry and Radiobiology, 10.2307/3577791
  16. Proc. 8th International Congress of Radiation Research, Edinburgh, July 1987
  17. Barendsen, Int. J. Radiat. Biol., 8, 453 (1964)
  18. Menzel Hans G., Wambersie Andre, Pihet Pascal, The Clinical Rbe and Microdosimetric Characterization of Radiation Quality in Fast Neutron Therapy, 10.3109/02841869409098415
  19. Mijnheer B.J., Battermann J.J., Wambersie A., What degree of accuracy is required and can be achieved in photon and neutron therapy?, 10.1016/s0167-8140(87)80247-5
  20. Schmitz, Radiat. Prot. Dosim., 61 (1995)
  21. Folkard M., Prise K.M., Vojnovic B., Davies S., Roper M.J., Michael B.D., The Irradiation of V79 Mammalian Cells by Protons with Energies below 2 MeV : Part I: Experimental Arrangement and Measurements of Cell Survival, 10.1080/09553008914551401
  22. FOLKARD, B. VOJNOVIC, K. M. PRISE, M., A charged-particle microbeam: I. Development of an experimental system for targeting cells individually with counted particles, 10.1080/095530097143158