User menu

Registration accuracy in computer-assisted pelvic surgery

Bibliographic reference Docquier, Pierre-Louis ; Paul, Laurent ; Cartiaux, Olivier ; Banse, Xavier. Registration accuracy in computer-assisted pelvic surgery. In: Computer Aided Surgery, Vol. 14, no. 1-3, p. 37-44 (2009)
Permanent URL http://hdl.handle.net/2078.1/34253
  1. Rajasekaran S, Vidyadhara S, Ramesh Perumal, Shetty Ajoy P., Randomized Clinical Study to Compare the Accuracy of Navigated and Non-Navigated Thoracic Pedicle Screws in Deformity Correction Surgeries : , 10.1097/01.brs.0000252094.64857.ab
  2. Kotani Yoshihisa, Abumi Kuniyoshi, Ito Manabu, Takahata Masahiko, Sudo Hideki, Ohshima Shigeki, Minami Akio, Accuracy Analysis of Pedicle Screw Placement in Posterior Scoliosis Surgery : Comparison Between Conventional Fluoroscopic and Computer-Assisted Technique, 10.1097/brs.0b013e318068661e
  3. Langlotz Frank, B??chler Richard, Berlemann Ulrich, Nolte Lutz-Peter, Ganz Reinhold, Computer Assistance for Pelvic Osteotomies : , 10.1097/00003086-199809000-00012
  4. Wong Kwok-Chuen, Kumta Shekhar Madhukar, Chiu Kwok-Hing, Cheung Kin-Wing, Leung Kwok-Siu, Unwin Paul, Wong Martin C. M., Computer assisted pelvic tumor resection and reconstruction with a custom-made prosthesis using an innovative adaptation and its validation, 10.3109/10929080701536046
  5. Krettek Christian, Geerling Jens, Bastian Leonard, Citak Musa, Rücker Ferdinand, Kendoff Daniel, Hüfner Tobias, Computer aided tumor resection in the pelvis, 10.1016/j.injury.2004.05.014
  6. Pakvis Dean, van Hellemondt Gijs, Anderson Patsy, de Kleuver Marinus, No benefits with computer assistance in triple pelvic osteotomy, 10.1080/00016470410001187
  7. van Hellemondt G., de Kleuver M., Kerckhaert A., Anderson P., Langlotz F., Nolte L. P., Pavlov P. W., Computer-Assisted Pelvic Surgery : An In Vitro Study of Two Registration Protocols, 10.1097/00003086-200212000-00036
  8. Sugano Nobuhiko, Sasama Toshihiko, Sato Yoshinobu, Nakajima Yoshikazu, Nishii Takashi, Yonenobu Kazuo, Tamura Shinichi, Ochi Takahiro, Accuracy Evaluation of Surface-Based Registration Methods in a Computer Navigation System for Hip Surgery Performed Through a Posterolateral Approach, 10.3109/10929080109146083
  9. Mayr E., The effect of fixation and location on the stability of the markers in navigated total hip arthroplasty: A CADAVER STUDY, 10.1302/0301-620x.88b2.17257
  10. Zitová Barbara, Flusser Jan, Image registration methods: a survey, 10.1016/s0262-8856(03)00137-9
  11. Herring J.L., Dawant B.M., Maurer C.R., Muratore D.M., Galloway R.L., Fitzpatrick J.M., Surface-based registration of CT images to physical space for image-guided surgery of the spine: a sensitivity study, 10.1109/42.736029