User menu

Accès à distance ? S'identifier sur le proxy UCLouvain

Experimental and theoretical dosimetry of a new polymer encapsulated iodine-125 source-SmartSeed : dosimetric impact of fluorescence x rays

  1. Rivard Mark J., Coursey Bert M., DeWerd Larry A., Hanson William F., Saiful Huq M., Ibbott Geoffrey S., Mitch Michael G., Nath Ravinder, Williamson Jeffrey F., Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations, 10.1118/1.1646040
  2. Seltzer S.M., Lamperti P.J., Loevinger R., Mitch M.G., Weaver J.T., Coursey B.M., New national air-kerma-strength standards for I-125 and Pd-103 brachytherapy seeds, 10.6028/jres.108.030
  3. B. J. Mijnheer A. H. L. Aalbers J. J. M. van Gasteren A. G. Visser F. W. Wittkämper Code of practice for the dosimetry of high energy photon beams 1986
  4. Reniers B, Vynckier S, Scalliet P, Dosimetric study of a new palladium seed, 10.1016/s0969-8043(02)00193-8
  5. Meigooni Ali S., Meli Jerome A., Nath Ravinder, A comparison of solid phantoms with water for dosimetry of 1 2 5 I brachytherapy sources : Comparison of solid phantoms with water for dosimetry, 10.1118/1.596182
  6. Abboud F., Scalliet P., Vynckier S., An experimental palladium-103 seed (OptiSeedexp) in a biocompatible polymer without a gold marker: Characterization of dosimetric parameters including the interseed effect : Dosimetric study of experimental seed, 10.1118/1.3006151
  7. Williamson, Phys. Med. Biol., 18, 776 (1991)
  8. ICRU 44 tissue substitutes in radiation dosimetry and measurement, international commission on radiation units and measurements 1989
  9. B. Reniers The use of low energy photons in brachytherapy: Dosimetric and microdosimetric studies around P 103 d and I 125 seeds 2005 63
  10. M. C. White Photoatomic data library MCPLIB04: A new photoatomic library based on data from ENDF/B-VI release 8 2002 http://www-xdiv.lanl.gov/PROJECTS/DATA/nuclear/pdf/mcw-02-111.pdf
  11. D. E. Cullen J. H. Hubbel L. D. Kissel EPDL97: The evaluated photon data library, ’97 version 6 1997
  12. ENDF Cross Section Evaluation Working Group ENDF/B-VI summary documentation (ENDF-201) 2000
  13. J. H. Hubbell J. S. Coursey J. Hwang D. S. Zucker 1998 http://physics.nist.gov/PhysRef-Data/photoncs/html/attencoef.html
  14. DeMarco John J, Wallace Robert E, Boedeker Kirsten, An analysis of MCNP cross-sections and tally methods for low-energy photon emitters, 10.1088/0031-9155/47/8/307
  15. Kubo Hideo, Exposure contribution from Ti K x rays produced in the titanium capsule of the clinical I-125 seed : Exposure contribution from Ti K x rays, 10.1118/1.595776
  16. Meigooni A. S., Sowards K., Soldano M., Dosimetric characteristics of the InterSource103palladium brachytherapy source, 10.1118/1.598991
  17. Valicenti R. K., Kirov A. S., Meigooni A. S., Mishra V., Das R. K., Williamson J. F., Experimental validation of Monte Carlo dose calculations about a high-intensity Ir-192 source for pulsed dose-rate brachytherapy, 10.1118/1.597484
  18. Williamson Jeffrey F., Monte Carlo modeling of the transverse-axis dose distribution of the Model 200 103Pd interstitial brachytherapy source, 10.1118/1.598924
  19. Medich David C., Tries Mark A., Munro John J., Monte Carlo characterization of an ytterbium-169 high dose rate brachytherapy source with analysis of statistical uncertainty : Dosimetric characterization of ytterbium-169 with analysis of uncertainty, 10.1118/1.2147767
  20. ICRU Stopping powers for electrons and positrons 1984
  21. ICRU Stopping power and ranges for protons and alpha particles 1993
  22. Nath Ravinder, Anderson Lowell L., Luxton Gary, Weaver Keith A., Williamson Jeffrey F., Meigooni Ali S., Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43, 10.1118/1.597458
  23. ESTAR-Stopping-power and range tables for electrons
  24. Reniers B., Vynckier S., Scalliet P., Dosimetric study of the new InterSource125iodine seed, 10.1118/1.1415072
  25. Hedtjärn Håkan, Carlsson Gudrun Alm, Williamson Jeffrey F., Monte Carlo-aided dosimetry of the symmetra model I25.S06 125I, interstitial brachytherapy seed, 10.1118/1.598990
  26. Taylor R. E. P., Yegin G., Rogers D. W. O., Benchmarking BrachyDose: Voxel based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters : Benchmarking the EGSnrc user-code BrachyDose, 10.1118/1.2400843
  27. Soares C G, Douysset G, Mitch M G, Primary standards and dosimetry protocols for brachytherapy sources, 10.1088/0026-1394/46/2/s06
Bibliographic reference Abboud, Fadi ; Scalliet, Pierre ; Hollows, M. ; Vynckier, Stefaan. Experimental and theoretical dosimetry of a new polymer encapsulated iodine-125 source-SmartSeed : dosimetric impact of fluorescence x rays. In: Medical Physics, Vol. 37, no. 5, p. 2054-2062 (2010)
Permanent URL http://hdl.handle.net/2078.1/33908