User menu

An experimental palladium-103 seed (OptiSeedexp) in a biocompatible polymer without a gold marker : characterization of dosimetric parameters including the interseed effect

Bibliographic reference Abboud, Fadi ; Scalliet, Pierre ; Vynckier, Stefaan. An experimental palladium-103 seed (OptiSeedexp) in a biocompatible polymer without a gold marker : characterization of dosimetric parameters including the interseed effect. In: Medical Physics, Vol. 35, no. 12, p. 5841-5850 (2008)
Permanent URL http://hdl.handle.net/2078.1/23057
  1. Rivard Mark J., Coursey Bert M., DeWerd Larry A., Hanson William F., Saiful Huq M., Ibbott Geoffrey S., Mitch Michael G., Nath Ravinder, Williamson Jeffrey F., Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations, 10.1118/1.1646040
  2. Reniers B, Vynckier S, Scalliet P, Dosimetric study of a new palladium seed, 10.1016/s0969-8043(02)00193-8
  3. Bernard S, Vynckier S, Dosimetric study of a new polymer encapsulated palladium-103 seed, 10.1088/0031-9155/50/7/012
  4. Stokes Steven H., Real Jack D., Adams Paul W., Clements Joseph C., Wuertzer Scott, Kan William, Transperineal ultrasound-guided radioactive seed implantation for organ-confined carcinoma of the prostate, 10.1016/s0360-3016(96)00508-1
  5. Hall Eric J., Radiation Dose-Rate: A Factor of Importance in Radiobiology and Radiotherapy, 10.1259/0007-1285-45-530-81
  6. Fontenla Doracy P., Ahmad Munir, Chiu-Tsao Sou-Tung, Anderson Lowell L., Diode dosimetry of 103 Pd model 200 seed in water phantom, 10.1118/1.597327
  7. Mobit Paul, Badragan Iulian, Dose perturbation effects in prostate seed implant brachytherapy with I-125, 10.1088/0031-9155/49/14/011
  8. Meigooni Ali S., Meli Jerome A., Nath Ravinder, A comparison of solid phantoms with water for dosimetry of 1 2 5 I brachytherapy sources : Comparison of solid phantoms with water for dosimetry, 10.1118/1.596182
  9. Williamson, Phys. Med. Biol., 18, 776 (1991)
  10. B. Reniers The use of low energy photons in brachytherapy: Dosimetric and microdosimetric studies around Pd 103 and I 125 seeds 2005
  11. Nath Ravinder, Anderson Lowell L., Luxton Gary, Weaver Keith A., Williamson Jeffrey F., Meigooni Ali S., Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43, 10.1118/1.597458
  12. E. Storm H. I. Israel Photon cross sections from 0.001 to 100 MeV for elements 1 through 100 1967
  13. Hubbell J. H., Veigele Wm. J., Briggs E. A., Brown R. T., Cromer D. T., Howerton R. J., Atomic form factors, incoherent scattering functions, and photon scattering cross sections, 10.1063/1.555523
  14. C. J. Everett E. D. Cashwell MCP code fluorescence-routine revision 1973
  15. Bohm Tim D., DeLuca Paul M., DeWerd Larry A., Brachytherapy dosimetry of 125I and 103Pd sources using an updated cross section library for the MCNP Monte Carlo transport code, 10.1118/1.1562942
  16. Reniers B, Verhaegen F, Vynckier S, The radial dose function of low-energy brachytherapy seeds in different solid phantoms: comparison between calculations with the EGSnrc and MCNP4C Monte Carlo codes and measurements, 10.1088/0031-9155/49/8/014
  17. DeMarco John J, Wallace Robert E, Boedeker Kirsten, An analysis of MCNP cross-sections and tally methods for low-energy photon emitters, 10.1088/0031-9155/47/8/307
  18. Reniers B., Vynckier S., Scalliet P., Dosimetric study of the new InterSource125iodine seed, 10.1118/1.1415072
  19. International Commission of Radiation Units and Measurements (ICRU) Tissue Substitutes in Radiation Dosimetry and Measurement 1989
  20. Meigooni A. S., Sowards K., Soldano M., Dosimetric characteristics of the InterSource103palladium brachytherapy source, 10.1118/1.598991
  21. J. H. Hubbell S. M. Seltzer Table of x-ray mass atomic attenuation coefficient and mass absorption coefficient 1 keV to 20 MeV for elements Z = 1 to 98 and 48 additional substances of dosimetric interest 1995
  22. Chibani, Med. Phys., 32, 3690 (2005)
  23. Wang Zhonglu, Hertel Nolan E., Determination of dosimetric characteristics of OptiSeedTM a plastic brachytherapy 103Pd source, 10.1016/j.apradiso.2005.03.017