User menu

Accès à distance ? S'identifier sur le proxy UCLouvain | Saint-Louis

Registration of Pencil Beam Proton Radiography Data With X-Ray CT

  1. Paganetti Harald, Range uncertainties in proton therapy and the role of Monte Carlo simulations, 10.1088/0031-9155/57/11/r99
  2. Knopf Antje-Christin, Lomax Antony, In vivoproton range verification: a review, 10.1088/0031-9155/58/15/r131
  3. Poludniowski G, Allinson N M, Evans P M, Proton radiography and tomography with application to proton therapy, 10.1259/bjr.20150134
  4. Rinaldi I, Brons S, Jäkel O, Voss B, Parodi K, Experimental investigations on carbon ion scanning radiography using a range telescope, 10.1088/0031-9155/59/12/3041
  5. Farace Paolo, Righetto Roberto, Meijers Arturs, Pencil beam proton radiography using a multilayer ionization chamber, 10.1088/0031-9155/61/11/4078
  6. Mumot M, Algranati C, Hartmann M, Schippers J M, Hug E, Lomax A J, Proton range verification using a range probe: definition of concept and initial analysis, 10.1088/0031-9155/55/16/010
  7. Schneider Uwe, Pemler Peter, Besserer Jürgen, Pedroni Eros, Lomax Antony, Kaser-Hotz Barbara, Patient specific optimization of the relation between CT-Hounsfield units and proton stopping power with proton radiography : Patient specific CT calibration with proton radiography, 10.1118/1.1833041
  8. Collins-Fekete CA, Brousmiche S, Hansen D, Beaulieu L, Seco J, SU-C-204-04: Patient Specific Proton Stopping Powers Estimation by Combining Proton Radiography and Prior-Knowledge X-Ray CT Information, 10.1118/1.4923828
  9. Doolan P J, Testa M, Sharp G, Bentefour E H, Royle G, Lu H-M, Patient-specific stopping power calibration for proton therapy planning based on single-detector proton radiography, 10.1088/0031-9155/60/5/1901
  10. Collins-Fekete C, Schulte R, Beaulieu L, Seco J, TU-FG-BRB-04: A New Optimization Method for Pre-Treatment Patient-Specific Stopping-Power by Combining Proton Radiography and X-Ray CT, 10.1118/1.4957544
  11. Farace Paolo, Righetto Roberto, Deffet Sylvain, Meijers Arturs, Vander Stappen Francois, Technical Note: A direct ray-tracing method to compute integral depth dose in pencil beam proton radiography with a multilayer ionization chamber : Direct ray-tracing in pencil beam proton radiography, 10.1118/1.4966703
  12. Markelj P., Tomaževič D., Likar B., Pernuš F., A review of 3D/2D registration methods for image-guided interventions, 10.1016/j.media.2010.03.005
  13. Unkelbach Jan, Bortfeld Thomas, Martin Benjamin C., Soukup Martin, Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning : Optimizing IMPT plans under uncertainty, 10.1118/1.3021139
  14. Krah N, Testa M, Brons S, Jäkel O, Parodi K, Voss B, Rinaldi I, An advanced image processing method to improve the spatial resolution of ion radiographies, 10.1088/0031-9155/60/21/8525
  15. Pflugfelder D., Wilkens J. J., Szymanowski H., Oelfke U., Quantifying lateral tissue heterogeneities in hadron therapy : Quantifying lateral tissue heterogeneities in hadron therapy, 10.1118/1.2710329
Bibliographic reference Deffet, Sylvain ; Macq, Benoît ; Righetto, Roberto ; Vander Stappen, François ; Farace, Paolo. Registration of Pencil Beam Proton Radiography Data With X-Ray CT. In: Medical Physics, (3/8/2017)
Permanent URL http://hdl.handle.net/2078.1/187299