Accès à distance ? S'identifier sur le proxy UCLouvain
Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study.
Primary tabs
Document type | Article de périodique (Journal article) – Article de recherche |
---|---|
Access type | Accès restreint |
Publication date | 2017 |
Language | Anglais |
Journal information | "European Spine Journal" - Vol. 26, no. 11, p. 2811-2817 (2017) |
Peer reviewed | yes |
Publisher | Springer-Verlag ((Germany) Heidelberg) |
issn | 0940-6719 |
e-issn | 1432-0932 |
Publication status | Publié |
Affiliations |
UCL
- (SLuc) Service d'orthopédie et de traumatologie de l'appareil locomoteur UCL - SSS/IREC/CARS - Computer Assisted Robotic Surgery UCL - SSS/IREC/NMSK - Neuro-musculo-skeletal Lab |
Keywords | Cone-beam CT ; Dose reduction strategies ; Intraoperative imaging ; Minimally invasive surgery ; Mobile C-arm ; Pedicle screws ; Radiation exposure |
Links |
- Tian Nai-Feng, Huang Qi-Shan, Zhou Ping, Zhou Yang, Wu Rui-Kai, Lou Yi, Xu Hua-Zi, Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies, 10.1007/s00586-010-1577-5
- Nelson Elisha M., Monazzam Shafagh M., Kim Kee D., Seibert J. Anthony, Klineberg Eric O., Intraoperative fluoroscopy, portable X-ray, and CT: patient and operating room personnel radiation exposure in spinal surgery, 10.1016/j.spinee.2014.06.003
- Ringel Florian, Villard Jimmy, Ryang Yu-Mi, Meyer Bernhard, Navigation, Robotics, and Intraoperative Imaging in Spinal Surgery, Advances and Technical Standards in Neurosurgery (2014) ISBN:9783319018294 p.3-22, 10.1007/978-3-319-01830-0_1
- Perisinakis Kostas, Theocharopoulos Nicholas, Damilakis John, Katonis Pavlos, Papadokostakis George, Hadjipavlou Alexandros, Gourtsoyiannis Nicholas, Estimation of Patient Dose and Associated Radiogenic Risks From Fluoroscopically Guided Pedicle Screw Insertion : , 10.1097/01.brs.0000131214.57597.21
- Hadelsberg Uri P., Harel Ran, Hazards of Ionizing Radiation and its Impact on Spine Surgery, 10.1016/j.wneu.2016.05.025
- IEC (2010) Report 60601 medical electrical equipment—part 2-43: particular requirements for the safety of X-ray equipment for interventional procedures, 2nd edn. International Electrotechnical Commission, Geneva
- Stecker Michael S., Balter Stephen, Towbin Richard B., Miller Donald L., Vañó Eliseo, Bartal Gabriel, Angle J. Fritz, Chao Christine P., Cohen Alan M., Dixon Robert G., Gross Kathleen, Hartnell George G., Schueler Beth, Statler John D., de Baère Thierry, Cardella John F., Guidelines for Patient Radiation Dose Management, 10.1016/j.jvir.2009.04.037
- Lee Kisung, Lee Kyoung Min, Park Moon Seok, Lee Boram, Kwon Dae Gyu, Chung Chin Youb, Measurements of Surgeonsʼ Exposure to Ionizing Radiation Dose During Intraoperative Use of C-Arm Fluoroscopy : , 10.1097/brs.0b013e31824589d5
- Mendelsohn Daniel, Strelzow Jason, Dea Nicolas, Ford Nancy L., Batke Juliet, Pennington Andrew, Yang Kaiyun, Ailon Tamir, Boyd Michael, Dvorak Marcel, Kwon Brian, Paquette Scott, Fisher Charles, Street John, Patient and surgeon radiation exposure during spinal instrumentation using intraoperative computed tomography-based navigation, 10.1016/j.spinee.2015.11.020
- Balter Stephen, Methods for measuring fluoroscopic skin dose, 10.1007/s00247-006-0193-3
- Harstall Roger, Heini Paul F., Mini Roberto L., Orler Rene, Radiation Exposure to the Surgeon During Fluoroscopically Assisted Percutaneous Vertebroplasty : A Prospective Study, 10.1097/01.brs.0000174121.48306.16
- Mulconrey Daniel S., Fluoroscopic Radiation Exposure in Spinal Surgery : In Vivo Evaluation for Operating Room Personnel, 10.1097/bsd.0b013e31828673c1
- Richter Peter H., Yarboro Seth, Kraus Michael, Gebhard Florian, One year orthopaedic trauma experience using an advanced interdisciplinary hybrid operating room, 10.1016/s0020-1383(15)30032-2
- Raftopoulos C., Waterkeyn F., Fomekong E., Duprez T., Percutaneous pedicle screw implantation for refractory low back pain: from manual 2D to fully robotic intraoperative 2D/3D fluoroscopy, Advances and Technical Standards in Neurosurgery (2012) ISBN:9783709106754 p.75-93, 10.1007/978-3-7091-0676-1_4
- Kraus Michael, Fischer Eric, Gebhard Florian, Richter Peter H., Image quality and effective dose of a robotic flat panel 3D C-arm vs computed tomography : Intraoperative 3D imaging in spine surgery, 10.1002/rcs.1718
- Gebhard Florian T., Kraus Michael D., Schneider Eugen, Liener Ulrich C., Kinzl Lothar, Arand Markus, Does Computer-Assisted Spine Surgery Reduce Intraoperative Radiation Doses? : , 10.1097/01.brs.0000229250.69369.ac
- Lange Jeffrey, Karellas Andrew, Street John, Eck Jason C., Lapinsky Anthony, Connolly Patrick J., DiPaola Christian P., Estimating the Effective Radiation Dose Imparted to Patients by Intraoperative Cone-Beam Computed Tomography in Thoracolumbar Spinal Surgery : , 10.1097/brs.0b013e318281d70b
- Rampersaud Y. Raja, Foley Kevin T., Shen Alfred C., Williams Scott, Solomito Milo, Radiation Exposure to the Spine Surgeon During Fluoroscopically Assisted Pedicle Screw Insertion : , 10.1097/00007632-200010150-00016
- Crawley M T, Rogers A T, Dose-area product measurements in a range of common orthopaedic procedures and their possible use in establishing local diagnostic reference levels., 10.1259/bjr.73.871.11089466
- Schafer S., Nithiananthan S., Mirota D. J., Uneri A., Stayman J. W., Zbijewski W., Schmidgunst C., Kleinszig G., Khanna A. J., Siewerdsen J. H., Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance : Mobile c-arm CBCT in spine surgery, 10.1118/1.3597566
- Bronsard N., Boli T., Challali M., de Dompsure R., Amoretti N., Padovani B., Bruneton G., Fuchs A., de Peretti F., Comparison between percutaneous and traditional fixation of lumbar spine fracture: Intraoperative radiation exposure levels and outcomes, 10.1016/j.otsr.2012.12.012
- Erken H. Yener, Burc Halil, Saka Gursel, Akmaz Ibrahim, Aydogan Mehmet, Can Radiation Exposure to the Surgeon Be Reduced With Freehand Pedicle Screw Fixation Technique in Pediatric Spinal Deformity Correction? A Prospective Multicenter Study : , 10.1097/brs.0000000000000172
- Ruatti Sébastien, Dubois C., Chipon E., Kerschbaumer G., Milaire M., Moreau-Gaudry A., Tonetti J., Merloz Ph., Interest of intra-operative 3D imaging in spine surgery: a prospective randomized study, 10.1007/s00586-015-4141-5
- Rayo Michael F., Patterson Emily S., Liston Beth W., White Susan, Kowalczyk Nina, Determining the Rate of Change in Exposure to Ionizing Radiation From CT Scans: A Database Analysis From One Hospital, 10.1016/j.jacr.2013.12.005
- Abul-Kasim Kasim, Söderberg Marcus, Selariu Eufrozina, Gunnarsson Mikael, Kherad Mehrsa, Ohlin Acke, Optimization of Radiation Exposure and Image Quality of the Cone-beam O-arm Intraoperative Imaging System in Spinal Surgery : , 10.1097/bsd.0b013e318211fdea
Bibliographic reference | Kaminski, Ludovic ; Cordemans, Virginie ; Cartiaux, Olivier ; Van Cauter, Maïté. Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study.. In: European Spine Journal, Vol. 26, no. 11, p. 2811-2817 (2017) |
---|---|
Permanent URL | http://hdl.handle.net/2078.1/183039 |