User menu

Pre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories

Bibliographic reference Magnette , A. ; Chatelain, Marc ; Chatelain, Bernard ; Ten Cate, H. ; Mullier, François. Pre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories. In: Thrombosis Journal, Vol. 12, no. 14, p. 49
Permanent URL http://hdl.handle.net/2078.1/179089
  1. Guder Walter G., History of the preanalytical phase: a personal view, 10.11613/bm.2014.005
  2. LOEFFEN R., KLEINEGRIS M.-C. F., LOUBELE S. T. B. G., PLUIJMEN P. H. M., FENS D., van OERLE R., ten CATE H., SPRONK H. M. H., Preanalytic variables of thrombin generation: towards a standard procedure and validation of the method : Preanalytic variables of thrombin generation, 10.1111/jth.12012
  3. Cornes M, van Dongen-Lases E, Grankvist K, Ibarz M, Kristensen G, Lippi G, Nybo M, Simundic AM, Working Group for Preanalytical Phase EFoCC, Laboratory M. Order of blood draw: Opinion Paper by the European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase (WG-PRE). Clin Chem Lab Med. 2016;55:27–31.
  4. Pre-Examination Procedures in Laboratory Diagnostics : Preanalytical Aspects and their Impact on the Quality of Medical Laboratory Results, ISBN:9783110334043, 10.1515/9783110334043
  5. Quality in Laboratory Hemostasis and Thrombosis : Kitchen/Quality, ISBN:9781118543467, 10.1002/9781118543467
  6. van Dongen-Lases EC, Cornes MP, Grankvist K, Ibarz M, Kristensen GB, Lippi G, Nybo M, Simundic AM. Working group for preanalytical phase EFoCC, laboratory M. Patient identification and tube labelling - a call for harmonisation. Clin Chem Lab Med. 2016;54:1141–5.
  7. RODEGHIERO F., TOSETTO A., ABSHIRE T., ARNOLD D. M., COLLER B., JAMES P., NEUNERT C., LILLICRAP D., , ISTH/SSC bleeding assessment tool: a standardized questionnaire and a proposal for a new bleeding score for inherited bleeding disorders : ISTH/SSC bleeding assessment tool, 10.1111/j.1538-7836.2010.03975.x
  8. Harrison Paul, Mackie Ian, Mumford Andrew, Briggs Carol, Liesner Ri, Winter Mark, Machin Sam, , Guidelines for the laboratory investigation of heritable disorders of platelet function : Guideline, 10.1111/j.1365-2141.2011.08793.x
  9. Bonhomme Fanny, Ajzenberg Nadine, Schved Jean-François, Molliex Serge, Samama Charles-Marc, Pre-interventional haemostatic assessment : Guidelines from the French Society of Anaesthesia and Intensive Care, 10.1097/eja.0b013e32835f66cd
  10. Tosetto A., Castaman G., Rodeghiero F., Bleeders, bleeding rates, and bleeding score, 10.1111/jth.12248
  11. Stepanian A, Biron-Andreani C. Primary hemostasis exploration. Ann Biol Clin (Paris). 2001;59:725–35.
  12. Haute Autorité de Santé. Biologie des anomalies de l’hémostase. Service évaluation des actes professionnels. 2010. V n°5 du 20/10/10.
  13. O'Donnell J., Laffan M. A., The relationship between ABO histo-blood group, factor VIII and von Willebrand factor, 10.1046/j.1365-3148.2001.00315.x
  14. Franchini Massimo, Capra Franco, Targher Giovanni, Montagnana Martina, Lippi Giuseppe, Relationship between ABO blood group and von Willebrand factor levels: from biology to clinical implications, 10.1186/1477-9560-5-14
  15. Cattaneo M., Cerletti C., Harrison P., Hayward C. P. M., Kenny D., Nugent D., Nurden P., Rao A. K., Schmaier A. H., Watson S. P., Lussana F., Pugliano M. T., Michelson A. D., Recommendations for the standardization of light transmission aggregometry: a consensus of the working party from the platelet physiology subcommittee of SSC/ISTH, 10.1111/jth.12231
  16. Ozgonenel B., Rajpurkar M., Lusher J. M, How do you treat bleeding disorders with desmopressin?, 10.1136/pgmj.2006.052118
  17. Lipets Elena N, Ataullakhanov Fazoil I, Global assays of hemostasis in the diagnostics of hypercoagulation and evaluation of thrombosis risk, 10.1186/s12959-015-0038-0
  18. Levine Amy B., Teppa Jose, McGough Becky, Cowchock F. Susan, Evaluation of the prethrombotic statein pregnancy and in women using oral contraceptives, 10.1016/s0010-7824(96)00057-1
  19. Brenner Benjamin, Haemostatic changes in pregnancy, 10.1016/j.thromres.2004.08.004
  20. Franchi Franca, Biguzzi Eugenia, Martinelli Ida, Bucciarelli Paolo, Palmucci Claudia, D’Agostino Simona, Peyvandi Flora, Normal reference ranges of antithrombin, protein C and protein S: Effect of sex, age and hormonal status, 10.1016/j.thromres.2013.07.003
  21. Sandset Per Morten, Mechanisms of hormonal therapy related thrombosis, 10.1016/s0049-3848(13)70009-4
  22. Raps M., Helmerhorst F. M., Fleischer K., Dahm A. E. A., Rosendaal F. R., Rosing J., Reitsma P., Sandset P. M., van Vliet H. A. A. M., The effect of different hormonal contraceptives on plasma levels of free protein S and free TFPI : , 10.1160/th12-10-0771
  23. VAN VLIET H. A. A. M., BERTINA R. M., DAHM A. E. A., ROSENDAAL F. R., ROSING J., MORTEN SANDSET P., HELMERHORST F. M., Different effects of oral contraceptives containing different progestogens on protein S and tissue factor pathway inhibitor, 10.1111/j.1538-7836.2008.02863.x
  24. Koenen RR, Christella M, Thomassen LG, Tans G, Rosing J, Hackeng TM. Effect of oral contraceptives on the anticoagulant activity of protein S in plasma. Thromb Haemost. 2005;93:853–9.
  25. Armstrong Elina, Joutsi-Korhonen Lotta, Lassila Riitta, Interaction between clinic and laboratory, 10.1016/s0049-3848(10)70146-8
  26. Centers for Disease Control and Prevention: http://www.cdc.gov . Accessed 17 Nov 2016.
  27. Castaman Giancarlo, Tosetto Alberto, Goodeve Anne, Federici Augusto B., Lethagen Stefan, Budde Ulrich, Batlle Javier, Meyer Dominique, Mazurier Claudine, Goudemand Jenny, Eikenboom Jeroen, Schneppenheim Reinhard, Ingerslev Jorgen, Habart David, Hill Frank, Peake Ian, Rodeghiero Francesco, The impact of bleeding history, von Willebrand factor and PFA-100® on the diagnosis of type 1 von Willebrand disease: results from the European study MCMDM-1VWD : PFA-100 for the Diagnosis of Type 1 VWD, 10.1111/j.1365-2141.2010.08333.x
  28. TOSETTO A., RODEGHIERO F., CASTAMAN G., GOODEVE A., FEDERICI A. B., BATLLE J., MEYER D., FRESSINAUD E., MAZURIER C., GOUDEMAND J., EIKENBOOM J., SCHNEPPENHEIM R., BUDDE U., INGERSLEV J., VORLOVA Z., HABART D., HOLMBERG L., LETHAGEN S., PASI J., HILL F., PEAKE I., A quantitative analysis of bleeding symptoms in type 1 von Willebrand disease: results from a multicenter European study (MCMDM-1 VWD), 10.1111/j.1538-7836.2006.01847.x
  29. RODEGHIERO F., CASTAMAN G., TOSETTO A., BATLLE J., BAUDO F., CAPPELLETTI A., CASANA P., DE BOSCH N., EIKENBOOM J. C. J., FEDERICI A. B., LETHAGEN S., LINARI S., SRIVASTAVA A., The discriminant power of bleeding history for the diagnosis of type 1 von Willebrand disease: an international, multicenter study, 10.1111/j.1538-7836.2005.01663.x
  30. Federici A. B., Bucciarelli P., Castaman G., Mazzucconi M. G., Morfini M., Rocino A., Schiavoni M., Peyvandi F., Rodeghiero F., Mannucci P. M., The bleeding score predicts clinical outcomes and replacement therapy in adults with von Willebrand disease, 10.1182/blood-2014-02-557264
  31. O′Brien EC, Simon DN, Thomas LE, Hylek EM, Gersh BJ, Ansell JE, Kowey PR, Mahaffey KW, Chang P, Fonarow GC, Pencina MJ, Piccini JP, Peterson ED. The ORBIT bleeding score: a simple bedside score to assess bleeding risk in atrial fibrillation. Eur Heart J. 2015;36:3258–64.
  32. Gresele P., , Diagnosis of inherited platelet function disorders: guidance from the SSC of the ISTH, 10.1111/jth.12792
  33. Gresele P., Harrison P., Bury L., Falcinelli E., Gachet C., Hayward C. P., Kenny D., Mezzano D., Mumford A. D., Nugent D., Nurden A. T., Orsini S., Cattaneo M., Diagnosis of suspected inherited platelet function disorders: results of a worldwide survey, 10.1111/jth.12650
  34. TOSETTO A., CASTAMAN G., PLUG I., RODEGHIERO F., EIKENBOOM J., Prospective evaluation of the clinical utility of quantitative bleeding severity assessment in patients referred for hemostatic evaluation : Bleeding score for the diagnosis of bleeding disorders, 10.1111/j.1538-7836.2011.04265.x
  35. Polack B, Schved JF, Boneu B. Groupe d’Etude sur l’Hemostase et la T. Preanalytical recommendations of the ‘Groupe d'Etude sur l'Hemostase et la Thrombose’ (GEHT) for venous blood testing in hemostasis laboratories. Haemostasis. 2001;31:61–8.
  36. GFHT. (French Study Group on Hemostasis and Thrombosis). 2015. http://site.geht.org/site/Pratiques-Professionnelles/Documents-GEHT/Variables-Preanalytiques/Recommandations-Variables-preanalytiques_69_722.html . Accessed 3 Nov 2016.
  37. Mullier F., Bailly N., Chatelain C., Chatelain B., Dogné J.-M., Pre-analytical issues in the measurement of circulating microparticles: current recommendations and pending questions, 10.1111/jth.12171
  38. Lima-Oliveira Gabriel, Salvagno Gian Luca, Lippi Giuseppe, Danese Elisa, Gelati Matteo, Montagnana Martina, Picheth Geraldo, Guidi Gian Cesare, Could light meal jeopardize laboratory coagulation tests?, 10.11613/bm.2014.036
  39. Rull Gurvinder, Mohd-Zain Zetty N., Shiel Julian, Lundberg Martina H., Collier David J., Johnston Atholl, Warner Timothy D., Corder Roger, Effects of high flavanol dark chocolate on cardiovascular function and platelet aggregation, 10.1016/j.vph.2015.02.010
  40. O'Donnell J, Tuddenham EG, Manning R, Kemball-Cook G, Johnson D, Laffan M. High prevalence of elevated factor VIII levels in patients referred for thrombophilia screening: role of increased synthesis and relationship to the acute phase reaction. Thromb Haemost. 1997;77:825–8.
  41. Lippi Giuseppe, Salvagno Gian, Montagnana Martina, Lima-Oliveira Gabriel, Guidi Gian, Favaloro Emmanuel, Quality Standards for Sample Collection in Coagulation Testing, 10.1055/s-0032-1315961
  42. Lee Kaeng W., Lip Gregory Y. H., Effects of Lifestyle on Hemostasis, Fibrinolysis, and Platelet Reactivity : A Systematic Review, 10.1001/archinte.163.19.2368
  43. Chen Y.-W., Chen J.-K., Wang J.-S., Strenuous exercise promotes shear-induced thrombin generation by increasing the shedding of procoagulant microparticles from platelets : , 10.1160/th09-09-0633
  44. McCRAW A., HILLARP A., ECHENAGUCIA M., Considerations in the laboratory assessment of haemostasis : LABORATORY ASSESSMENT OF HAEMOSTASIS, 10.1111/j.1365-2516.2010.02302.x
  45. Lippi G, Becan-McBride K, Behulova D, Bowen RA, Church S, Delanghe J, Grankvist K, Kitchen S, Nybo M, Nauck M, Nikolac N, Palicka V, Plebani M, Sandberg S, Simundic AM. Preanalytical quality improvement: in quality we trust. Clin Chem Lab Med. 2013;51:229–41.
  46. WHO Guidelines on Drawing Blood: Best Practices in Phlebotomy. Geneva; 2010. http://www.euro.who.int/__data/assets/pdf_file/0005/268790/WHO-guidelines-on-drawing-blood-best-practices-in-phlebotomy-Eng.pdf?ua=1 .
  47. CLSI GP41-A6 (replaces H03-A6). Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture; Approved Standard—Sixth Edition. Vol. 27 No. 26.
  48. Lima-Oliveira Gabriel, Lippi Giuseppe, Salvagno Gian Luca, Montagnana Martina, Picheth Geraldo, Guidi Gian Cesare, The effective reduction of tourniquet application time after minor modification of the CLSI H03-A6 blood collection procedure, 10.11613/bm.2013.037
  49. Mackie I., Cooper P., Lawrie A., Kitchen S., Gray E., Laffan M., , Guidelines on the laboratory aspects of assays used in haemostasis and thrombosis, 10.1111/ijlh.12004
  50. Riley RS, Tidwell AR, Williams D, Bode AP, Carr ME. Laboratory Evaluation of Hemostasis. http://www.pathology.vcu.edu/media/pathology/clinical/coag/LabHemostasis.pdf .
  51. Lippi Giuseppe, Ippolito Luigi, Zobbi Valentina, Sandei Franca, Favaloro Emmanuel J., Sample collection and platelet function testing : influence of vacuum or aspiration principle on PFA-100 test results, 10.1097/mbc.0b013e32835fada7
  52. Becton, Dickinson and Company (BD) Diagnostics : http://www.bd.com . Accessed 17 Nov 2016.
  53. LIPPI G., SALVAGNO G. L., ADCOCK D. M., GELATI M., GUIDI G. C., FAVALORO E. J., Right or wrong sample received for coagulation testing? Tentative algorithms for detection of an incorrect type of sample, 10.1111/j.1751-553x.2009.01142.x
  54. Smock Kristi J, Crist Ronda A, Hansen Sarah J, Rodgers George M, Lehman Christopher M, Discard tubes are not necessary when drawing samples for specialized coagulation testing : , 10.1097/mbc.0b013e3283380d12
  55. Raijmakers Maarten T.M., Menting Carolien H.F., Vader Huib L., van der Graaf Fedde, Collection of Blood Specimens by Venipuncture for Plasma-Based Coagulation Assays : Necessity of a Discard Tube, 10.1309/ajcp9atb0axpfjcc
  56. Adcock Dorothy M., Kressin David C., Marlar Richard A., Minimum Specimen Volume Requirements for Routine Coagulation Testing:Dependence on Citrate Concentration, 10.1093/ajcp/109.5.595
  57. CLSI H21-A5: Collection, Transport, and Processing of Blood Specimens for Testing Plasma-Based Coagulation Assays and Molecular Hemostasis Assays; Approved Guideline—Fifth Edition. Vol. 28 No. 5.
  58. ERNST DENNIS J., ERNST CATHERINE, Phlebotomy Tools of the Trade: Part 4 : Proper Handling and Storage of Blood Specimens, 10.1097/00004045-200304000-00014
  59. Arora S, Kolte S, Dhupia J. Hemolyzed samples should be processed for coagulation studies: the study of hemolysis effects on coagulation parameters. Ann Med Health Sci Res. 2014;4:233–7.
  60. Favaloro Emmanuel J., (Adcock) Funk Dorothy M., Lippi Giuseppe, Pre-analytical Variables in Coagulation Testing Associated With Diagnostic Errors in Hemostasis, 10.1309/lm749bqetkypypvm
  61. Lippi G, Plebani M, Favaloro EJ. Interference in coagulation testing: focus on spurious hemolysis, icterus, and lipemia. Semin Thromb Hemost. 2013;39:258–66.
  62. LACROIX R., JUDICONE C., PONCELET P., ROBERT S., ARNAUD L., SAMPOL J., DIGNAT-GEORGE F., Impact of pre-analytical parameters on the measurement of circulating microparticles: towards standardization of protocol : Pre-analytics influence on microparticles analysis, 10.1111/j.1538-7836.2011.04610.x
  63. Lacroix R., Judicone C., Mooberry M., Boucekine M., Key N. S., Dignat-George F., , Standardization of pre-analytical variables in plasma microparticle determination: results of the International Society on Thrombosis and Haemostasis SSC Collaborative workshop, 10.1111/jth.12207
  64. Adcock Funk Dorothy, Lippi Giuseppe, Favaloro Emmanuel, Quality Standards for Sample Processing, Transportation, and Storage in Hemostasis Testing, 10.1055/s-0032-1319768
  65. Bolliger Daniel, Seeberger Manfred D., Tanaka Kenichi A., Dell-Kuster Salome, Gregor Michael, Zenklusen Urs, Grapow Martin, Tsakiris Dimitrios A., Filipovic Miodrag, Pre-analytical effects of pneumatic tube transport on impedance platelet aggregometry, 10.3109/09537100903236462
  66. Lance M. D., Henskens Y. M. C., Effect of pneumatic tube transport on rotational thromboelastometry, 10.1093/bja/aes439
  67. Lancé Marcus D., Kuiper Gerhardus J.A.J.M., Sloep Matthijs, Spronk Henri M.H., van Oerle René, ten Cate Hugo, Marcus Marco A.E., Henskens Yvonne M.C., The effects of pneumatic tube system transport on ROTEM analysis and contact activation assessed by thrombin generation test, 10.1016/j.thromres.2012.05.002
  68. Lancé M. D., Marcus M. A. E., van Oerle R., Theunissen H. M. S., Henskens Y. M. C., Platelet concentrate transport in pneumatic tube systems - does it work? : Platelet concentrate tube transport, 10.1111/j.1423-0410.2011.01580.x
  69. Daves Massimo, Giacomuzzi Katia, Tagnin Enrico, Jani Erika, Adcock Funk Dorothy M., Favaloro Emmanuel J., Lippi Giuseppe, Influence of centrifuge brake on residual platelet count and routine coagulation tests in citrated plasma : , 10.1097/mbc.0000000000000026
  70. Nelson S, Pritt A, Marlar RA. Rapid preparation of plasma for ‘Stat’ coagulation testing. Arch Pathol Lab Med. 1994;118:175–6.
  71. Pappas AA, Palmer SK, Meece D, Fink LM. Rapid preparation of plasma for coagulation testing. Arch Pathol Lab Med. 1991;115:816–7.
  72. Lippi Giuseppe, Franchini Massimo, Montagnana Martina, Salvagno Gian Luca, Poli Giovanni, Guidi Gian Cesare, Quality and reliability of routine coagulation testing: can we trust that sample? : , 10.1097/01.mbc.0000245290.57021.46
  73. Lippi Giuseppe, Favaloro Emmanuel, Sanchis-Gomar Fabian, Venous Thrombosis Associated with HMG-CoA Reductase Inhibitors, 10.1055/s-0033-1343892
  74. Lippi Giuseppe, Salvagno Gian Luca, Montagnana Martina, Manzato Franco, Guidi Gian Cesare, Influence of the centrifuge time of primary plasma tubes on routine coagulation testing : , 10.1097/mbc.0b013e3281eec945
  75. Boudaoud L, Divaret G, Marie P, Bezeaud A. Rapid centrifugation for routine coagulation testing. Ann Biol Clin (Paris). 2006;64:315–7.
  76. Sultan A. Five-minute preparation of platelet-poor plasma for routine coagulation testing. East Mediterr Health J. 2010;16:233–6.
  77. Ageno W., Büller H. R., Falanga A., Hacke W., Hendriks J., Lobban T., Merino J., Milojevic I. S., Moya F., van der Worp H. B., Randall G., Tsioufis K., Verhamme P., Camm A. J., Managing reversal of direct oral anticoagulants in emergency situations : Anticoagulation Education Task Force White Paper, 10.1160/th16-05-0363
  78. Pollack Charles V., Reilly Paul A., Eikelboom John, Glund Stephan, Verhamme Peter, Bernstein Richard A., Dubiel Robert, Huisman Menno V., Hylek Elaine M., Kamphuisen Pieter W., Kreuzer Jörg, Levy Jerrold H., Sellke Frank W., Stangier Joachim, Steiner Thorsten, Wang Bushi, Kam Chak-Wah, Weitz Jeffrey I., Idarucizumab for Dabigatran Reversal, 10.1056/nejmoa1502000
  79. Suchsland Juliane, Friedrich Nele, Grotevendt Anne, Kallner Anders, Lüdemann Jan, Nauck Matthias, Petersmann Astrid, Optimizing centrifugation of coagulation samples in laboratory automation, 10.1515/cclm-2014-0038
  80. Mayo Medical Laboratories. Ensuring Specimen Integrity: Proper Processing and Handling of Specimens for Coagulation Testing. http://www.mayomedicallaboratories.com/articles/communique/2008/10update1.html .
  81. SALVAGNO G. L., LIPPI G., MONTAGNANA M., FRANCHINI M., POLI G., GUIDI G. C., Influence of temperature and time before centrifugation of specimens for routine coagulation testing, 10.1111/j.1751-553x.2008.01058.x
  82. Böhm Martina, Täschner Susanne, Kretzschmar Evelyne, Gerlach Rüdiger, Favaloro Emmanuel J, Scharrer Inge, Cold storage of citrated whole blood induces drastic time-dependent losses in factor VIII and von Willebrand factor: potential for misdiagnosis of haemophilia and von Willebrand disease : , 10.1097/01.mbc.0000198990.16598.85
  83. Kottke-Marchant K, David B. Laboratory hematology practice. Wiley-Blackwell. 2012;31:416–7.
  84. Zurcher M, Sulzer I, Barizzi G, Lammle B, Alberio L. Stability of coagulation assays performed in plasma from citrated whole blood transported at ambient temperature. Thromb Haemost. 2008;99:416–26.
  85. Rao L.V, Okorodudu A.O, Petersen J.R, Elghetany M.T, Stability of prothrombin time and activated partial thromboplastin time tests under different storage conditions, 10.1016/s0009-8981(00)00288-6
  86. Alesci Sonja, Borggrefe Martin, Dempfle Carl-Erik, Effect of freezing method and storage at −20 °C and −70 °C on prothrombin time, aPTT and plasma fibrinogen levels, 10.1016/j.thromres.2008.11.010
  87. Bach Juergen, Haubelt Hanne, Hellstern Peter, Sources of variation in factor VIII, von Willebrand factor and fibrinogen measurements: Implications for detecting deficiencies and increased plasma levels, 10.1016/j.thromres.2010.05.029
  88. Marlar R. A., Gausman J. N., Laboratory testing issues for protein C, protein S, and antithrombin, 10.1111/ijlh.12219
  89. A Practical Guide to Laboratory Haemostasis: http://www.practical-haemostasis.com/index.html . Accessed 17 Nov 2016.