User menu

Alignment in total knee arthroplasty, still more questions than answers ...

Bibliographic reference Thienpont, Emmanuel ; Bellemans, Johan ; Victor, Jan ; Becker, Roland. Alignment in total knee arthroplasty, still more questions than answers .... In: Knee Surgery, Sports Traumatology, Arthroscopy, Vol. 21, no.10, p. 2191-2193 (2013)
Permanent URL http://hdl.handle.net/2078.1/155180
  1. Barrack R. L., Ruh E. L., Williams B. M., Ford A. D., Foreman K., Nunley R. M., Patient specific cutting blocks are currently of no proven value, 10.1302/0301-620x.94b11.30834
  2. Bellemans Johan, Colyn William, Vandenneucker Hilde, Victor Jan, The Chitranjan Ranawat Award: Is Neutral Mechanical Alignment Normal for All Patients?: The Concept of Constitutional Varus, 10.1007/s11999-011-1936-5
  3. Bellemans Johan, Navigation and CAS: is D-Day approaching?, 10.1007/s00167-009-0897-7
  4. Boonen B., Schotanus M. G. M., Kerens B., van der Weegen W., van Drumpt R. A. M., Kort N. P., Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial, 10.1007/s00167-013-2620-y
  5. Chareancholvanich K, Narkbunnam R, Pornrattanamaneewong C (2013) A prospective randomized controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. Bone Joint J 95:345–349
  6. Fu Yonghui, Wang Mingming, Liu Yifeng, Fu Qin, Alignment outcomes in navigated total knee arthroplasty: a meta-analysis, 10.1007/s00167-011-1695-6
  7. Howell Stephen M., Howell Stacey J., Kuznik Kyle T., Cohen Joe, Hull Maury L., Does A Kinematically Aligned Total Knee Arthroplasty Restore Function Without Failure Regardless of Alignment Category?, 10.1007/s11999-012-2613-z
  8. Howell Stephen M., Papadopoulos Stelios, Kuznik Kyle T., Hull Maury L., Accurate alignment and high function after kinematically aligned TKA performed with generic instruments, 10.1007/s00167-013-2621-x
  9. Lützner Jörg, Dexel Julian, Kirschner Stephan, No difference between computer-assisted and conventional total knee arthroplasty: five-year results of a prospective randomised study, 10.1007/s00167-013-2608-7
  10. Nunley Ryan M., Ellison Bradley S., Zhu Jinjun, Ruh Erin L., Howell Stephen M., Barrack Robert L., Do Patient-specific Guides Improve Coronal Alignment in Total Knee Arthroplasty?, 10.1007/s11999-011-2222-2
  11. Parratte Sebastien, Pagnano Mark W, Trousdale Robert T, Berry Daniel J, Effect of Postoperative Mechanical Axis Alignment on the Fifteen-Year Survival of Modern, Cemented Total Knee Replacements : , 10.2106/jbjs.i.01398
  12. Pietsch M., Djahani O., Hochegger M., Plattner F., Hofmann S., Patient-specific total knee arthroplasty: the importance of planning by the surgeon, 10.1007/s00167-013-2624-7
  13. Ritter Merrill A, Davis Kenneth E, Meding John B, Pierson Jeffery L, Berend Michael E, Malinzak Robert A, The Effect of Alignment and BMI on Failure of Total Knee Replacement : , 10.2106/jbjs.j.00772
  14. Rosenberger Ralf E., Hoser Christian, Quirbach Sebastian, Attal Rene, Hennerbichler Alfred, Fink Christian, Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty, 10.1007/s00167-007-0420-y
  15. Vanlommel L, Vanlommel J, Claes S, Bellemans J (2013) Slight undercorrection following total knee arthroplasty results in superior clinical outcomes in varus knees. Knee Surg Sports Traumatol Arthrosc. doi: 10.1007/s00167-013-2481-4
  16. Victor J, Dujardin J, Vandenneucker H, Arnout N, Bellemans J (2013) Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective controlled trial. Clin Orthop Relat Res. doi: 10.1007/s11999-013-2997-4
  17. Wylde Vikki, Hewlett Sarah, Learmonth Ian D., Dieppe Paul, Persistent pain after joint replacement: Prevalence, sensory qualities, and postoperative determinants : , 10.1016/j.pain.2010.11.023
  18. Yau W. P., Chiu K. Y., Cutting errors in total knee replacement: assessment by computer assisted surgery, 10.1007/s00167-008-0550-x