User menu

Calibration of gamma camera systems for a multicentre European ¹²³I-FP-CIT SPECT normal database.

Bibliographic reference Tossici-Bolt, Livia ; Dickson, John C ; Sera, Terez ; de Nijs, Robin ; Bagnara, Maria Claudia ; et. al. Calibration of gamma camera systems for a multicentre European ¹²³I-FP-CIT SPECT normal database.. In: European journal of nuclear medicine and molecular imaging, Vol. 38, no.8, p. 1529-40 (2011)
Permanent URL http://hdl.handle.net/2078.1/123239
  1. Benamer Hani T. S., Patterson Jim, Grosset Donald G., Booij J., de Bruin K., van Royen E., Speelman J. D., Horstink M. H. I. M., Sips H. J. W. A., Dierckx R. A., Versijpt J., Decoo D., Van Der Linden C., Hadley D. M., Doder M., Lees A. J., Costa D. C., Gacinovic S., Oertel W. H., Pogarell O., Hoeffken H., Joseph K., Tatsch K., Schwarz J., Ries V., Accurate differentiation of parkinsonism and essential tremor using visual assessment of [123I]-FP-CIT SPECT imaging: The [123I]-FP-CIT study group, 10.1002/1531-8257(200005)15:3<503::aid-mds1013>3.0.co;2-v
  2. Catafau Ana M., Tolosa Eduardo, , Impact of dopamine transporter SPECT using123I-Ioflupane on diagnosis and management of patients with clinically uncertain parkinsonian syndromes, 10.1002/mds.20112
  3. McKeith Ian, O'Brien John, Walker Zuzana, Tatsch Klaus, Booij Jan, Darcourt Jacques, Padovani Alessandro, Giubbini Raffaele, Bonuccelli Ubaldo, Volterrani Duccio, Holmes Clive, Kemp Paul, Tabet Naji, Meyer Ines, Reininger Cornelia, Sensitivity and specificity of dopamine transporter imaging with 123I-FP-CIT SPECT in dementia with Lewy bodies: a phase III, multicentre study, 10.1016/s1474-4422(07)70057-1
  4. van Dyck Christopher H., Seibyl John P., Malison Robert T., Laruelle Marc, Zoghbi Sami S., Baldwin Ronald M., Innis Robert B., Age-Related Decline in Dopamine Transporters: Analysis of Striatal Subregions, Nonlinear Effects, and Hemispheric Asymmetries, 10.1097/00019442-200201000-00005
  5. Meyer PT, Sattler B, Lincke T, Seese A, Sabri O. Investigating dopaminergic neurotransmission with 123I-FP-CIT SPECT: comparability of modern SPECT systems. J Nucl Med 2003;44:839–45.
  6. Koch Walter, Radau Perry E, Münzing Wolfgang, Tatsch Klaus, Cross-camera comparison of SPECT measurements of a 3-D anthropomorphic basal ganglia phantom, 10.1007/s00259-005-0036-8
  7. Varrone Andrea, Sansone Valeria, Pellecchia Maria Teresa, Amboni Marianna, Salvatore Elena, De Michele Giuseppe, Filla Alessandro, Barone Paolo, Pappatà Sabina, Salvatore Marco, Comparison between a dual-head and a brain-dedicated SPECT system in the measurement of the loss of dopamine transporters with [123I]FP-CIT, 10.1007/s00259-008-0729-x
  8. Ogawa K., Harata Y., Ichihara T., Kubo A., Hashimoto S., A practical method for position-dependent Compton-scatter correction in single photon emission CT, 10.1109/42.97591
  9. Ichihara T, Ogawa K, Motomura N, Kubo A, Hashimoto S. Compton scatter compensation using the triple-energy window method for single- and dual-isotope SPECT. J Nucl Med 1993;34:2216–21.
  10. Hudson H.M., Larkin R.S., Accelerated image reconstruction using ordered subsets of projection data, 10.1109/42.363108
  11. Dickson John C., Tossici-Bolt Livia, Sera Terez, Erlandsson Kjell, Varrone Andrea, Tatsch Klaus, Hutton Brian F., The impact of reconstruction method on the quantification of DaTSCAN images, 10.1007/s00259-009-1212-z
  12. Cot A, Falcón C, Crespo C, Sempau J, Pareto D, Bullich S, et al. Absolute quantification in dopaminergic neurotransmission SPECT using a Monte Carlo-based scatter correction and fully 3-dimensional reconstruction. J Nucl Med 2005;46:1497–504.
  13. Van Laere Koen, Varrone Andrea, Booij Jan, Vander Borght Thierry, Nobili Flavio, Kapucu Özlem L., Walker Zuzana, Någren Kjell, Tatsch Klaus, Darcourt Jacques, EANM procedure guidelines for brain neurotransmission SPECT/PET using dopamine D2 receptor ligands, version 2, 10.1007/s00259-009-1265-z
  14. Tossici-Bolt Livia, Hoffmann Sandra M. A., Kemp Paul M., Mehta Rajnikant L., Fleming John S., Quantification of [123I]FP-CIT SPECT brain images: an accurate technique for measurement of the specific binding ratio, 10.1007/s00259-006-0155-x
  15. Fleming John S, Bolt Livia, Stratford Jennifer S, Kemp Paul M, The specific uptake size index for quantifying radiopharmaceutical uptake, 10.1088/0031-9155/49/14/n03
  16. Fleiss JL. Statistical methods for rates and proportions. 2nd ed. New York: Wiley; 1981.
  17. Crespo Cristina, Gallego Judith, Cot Albert, Falcón Carles, Bullich Santiago, Pareto Deborah, Aguiar Pablo, Sempau Josep, Lomeña Francisco, Calviño Francisco, Pavía Javier, Ros Domènec, Quantification of dopaminergic neurotransmission SPECT studies with 123I-labelled radioligands. A comparison between different imaging systems and data acquisition protocols using Monte Carlo simulation, 10.1007/s00259-007-0711-z
  18. Dobbeleir André A., Hambÿe Anne-Sophie E., Franken Philippe R., Influence of high-energy photons on the spectrum of iodine-123 with low- and medium-energy collimators: consequences for imaging with 123 I-labelled compounds in clinical practice, 10.1007/s002590050434
  19. HASHIMOTO J., SASAKI T., OGAWA K., KUBO A., MOTOMURA N., ICHIHARA T., AMANO T., FUKUUCHI Y., Effects of scatter and attenuation correction on quantitative analysis of β-CIT brain SPET : , 10.1097/00006231-199902000-00008
  20. Fujita Masahiro, Varrone Andrea, Kim Kyeong Min, Watabe Hiroshi, Zoghbi Sami S., Seneca Nicholas, Tipre Dnyanesh, Seibyl John P., Innis Robert B., Iida Hidehiro, Effect of scatter correction on the compartmental measurement of striatal and extrastriatal dopamine D 2 receptors using [ 123 I]epidepride SPET, 10.1007/s00259-003-1431-7
  21. Fleming JS, Alaamer AS. Influence of collimator characteristics on quantification in SPECT. J Nucl Med 1996;37:1832–6.
  22. INOUE Y, SHIROUZU I, MACHIDA T, YOSHIZAWA Y, AKITA F, DOI I, WATADANI T, NODA M, YOSHIKAWA K, OHTOMO K, Physical characteristics of low and medium energy collimators for 123I imaging and simultaneous dual-isotope imaging : , 10.1097/00006231-200311000-00011
  23. de Nijs Robin, Holm Søren, Thomsen Gerda, Ziebell Morten, Svarer Claus, Experimental determination of the weighting factor for the energy window subtraction-based downscatter correction for I-123 in brain SPECT studies, 10.4103/0971-6203.71765
  24. Tanaka Minoru, Uehara Shuzo, Kojima Akihiro, Matsumoto Masanori, Monte Carlo simulation of energy spectra for123I imaging, 10.1088/0031-9155/52/15/004
  25. de Nijs R, Svarer C. Combined backscatter and scatter correction for low count I-123 SPECT studies. J Nucl Med 2007;48(Suppl 2):424P.
  26. Soret M, Koulibaly PM, Darcourt J, Hapdey S, Buvat I. Quantitative accuracy of dopaminergic neurotransmission imaging with (123)I SPECT. J Nucl Med 2003;44:1184–93.
  27. Cot A, Sempau J, Pareto D, Bullich S, Pavía J, Calviño F, Ros D, Study of the point spread function (PSF) for 123I SPECT imaging using Monte Carlo simulation, 10.1088/0031-9155/49/14/007
  28. Zaidi Habib, Koral Kenneth F., Scatter modelling and compensation in emission tomography, 10.1007/s00259-004-1495-z
  29. Larsson Anne, Ljungberg Michael, Mo Susanna Jakobson, Riklund Katrine, Johansson Lennart, Correction for scatter and septal penetration using convolution subtraction methods and model-based compensation in 123I brain SPECT imaging—a Monte Carlo study, 10.1088/0031-9155/51/22/003
  30. Rousset OG, Zaidi H. Correction for partial volume effects in emission tomography. In: Quantitative analysis in nuclear medicine imaging. New York: Springer; 2006. p. 236–71.
  31. Soret Marine, Koulibaly Pierre Malick, Darcourt Jacques, Buvat Irène, Partial volume effect correction in SPECT for striatal uptake measurements in patients with neurodegenerative diseases: impact upon patient classification, 10.1007/s00259-005-0003-4
  32. Erlandsson K, Thomas B, Dickson J, Hutton BF. Partial volume correction in SPECT reconstruction with OSEM. Nucl Instrum Methods Phys Res A 2010. doi: 10.1016/j.nima.2010.12.106 .
  33. Blinkov SM, Glezer II. The human brain in figures and tables. A quantitative handbook. New York: Plenum; 1968. p. 166–71.
  34. Aylward Elizabeth H., Li Qiang, Habbak Reem, Warren Andrew, Pulsifer Margaret B., Barta Patrick E., Jerram Matthew, Pearlson Godfrey, Basal ganglia volume in adults with Down syndrome, 10.1016/s0925-4927(97)00011-5