Online brain attenuation correction in PET: towards a fully automated data handling in a clinical environment.

Bibliographic reference Michel, Christian ; Bol, Anne ; De Volder, Anne ; Goffinet, André. Online brain attenuation correction in PET: towards a fully automated data handling in a clinical environment.. In: European journal of nuclear medicine, Vol. 15, no. 11, p. 712-8 (1989)
Permanent URL http://hdl.handle.net/2078.1/11606
  1. Bergström M, Litton J, Eriksson L, Bohm C, Blomqvist G (1982) Determination of object contour from projections for attenuation correction in cranial positron emission tomography. J Comput Assist Tomogr 6:365?372
  2. Bergström M, Eriksson L, Bohm C, Blomqvist G, Litton J (1983) Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections. J Comput Assist Tomogr 7:42?50
  3. Casey M, Hoffman EJ (1986) Quantitation in positron emission tomography: 7. A technique to reduce noise in accidental coincidence measurements and coincidence efficiency calibration. J Comput Assist Tomogr 10:845?850
  4. Chan B, Bergström M, Palmer MR, Sayre C, Pate BD (1986) Scatter distribution in transmission measurements with positron emission tomography. J Comput Assist Tomogr 10:296?301
  5. Cho ZH, Chan JK, Eriksson L, Singh M, Graham S, MacDonald NS, Yano Y (1975) Positron range obtained from biomedically important positron-emitting radionuclides. J Nucl Med 16:1174?1176
  6. Dahlbom M, Hoffman EJ (1987) Problems in signal-to-noise ratio for attenuation correction in high resolution PET. IEEE Trans Nucl Sci NS-34:288?293
  7. Derenzo SE, Budinger TF, Huesman RH, Cahoon JL, Vueltich T (1981) Imaging properties of a positron tomography with 280 BGO crystals. IEEE Trans Nucl Sci NS-28:81?89
  8. Friedman JH (1974) Data analysis for high energy particle physics, proceeding of the CERN School of Computing, Godoysund. Norway (CERN Report 74-23)
  9. Germano G, Hoffman EJ (1988) Investigation of count rate and deadtime characteristics of a high resolution pet system. J Comput Assist Tomogr 12:836?846
  10. Gonzalez RC, Wintz P (1987) Digital image processing, 2nd Ed. Addison-Wesley, Reading, MA
  11. Huang SC, Hoffman EJ, Phelps ME, Kuhl DE (1979) Quantitation in positron emission tomography: 2. Effects of inaccurate attenuation correction. J Comput Assist Tomogr 3:804?814
  12. Huang SC, Carson RE, Phelps ME, Hoffman EJ, Schelbert HR, Kuhl DE (1981) A boundary method for attenuation correction in positron computed tomography. J Nucl Med 22:627?637
  13. Huesman RH, Derenzo SE, Cahoon JL, Geyer AB, Moses WW, Uber DC, Vuletich T, Budinger TF (1988) Orbiting transmission source for positron tomography. IEEE Trans Nucl Sci NS-35:735?739
  14. Hoffman EJ, Phelps ME, Huang SC, Collard PE, Bidaut LM, Schwab RL, Ricci AR (1986) Dynamic gated and high resolution imaging with the ECAT III. IEEE Trans Nucl Sci NS-33:452?455
  15. Hosoba M, Wani H, Toyama H, Murata H, Tanaka E (1986) Automated body contour detection in SPECT: effect on quantitative studies. J Nucl Med 27:1184?1191
  16. King PH, Hubner K, Gibbs W, Holloway E (1981) Noise identification and removal in positron imaging systems. IEEE Trans Nucl Sci NS-28:148?151
  17. Kretschmann HJ, Weinrich W (1986) Neuroanatomy and cranial computed tomography, 1st Ed. Thieme, Stuttgart, New York
  18. Press WH, Flannery BP, Teukolsky SA, Vetterling WT (1986) Numerical Recipes ? The Art of Scientific Computing, Cambridge University Press, Cambridge
  19. Tomitani T (1987) An edge detection algorithm for attenuation correction in emission CT. IEEE Trans Nucl Sci NS-34:309?312