User menu

Accès à distance ? S'identifier sur le proxy UCLouvain

Development of biocompatible oxygen-permeable films holding paramagnetic carbon particles: evaluation of their performance and stability in EPR oximetry.

  1. Liu K. J., Gast P., Moussavi M., Norby S. W., Vahidi N., Walczak T., Wu M., Swartz H. M., Lithium phthalocyanine: a probe for electron paramagnetic resonance oximetry in viable biological systems., 10.1073/pnas.90.12.5438
  2. Vahidi N., Clarkson R. B., Liu K. J., Norby S. W., Wu M., Swartz H. M., In Vivo andin vitro EPR oximetry with fusinite: A new coal-derived, particulate EPR probe, 10.1002/mrm.1910310207
  3. James Philip E., Grinberg Oleg Y., Goda Fuminori, Panz Tomasz, O'Hara Julia A., Swartz Harold M., Gloxy: An oxygen-sensitive coal for accurate measurement of low oxygen tensions in biological systems, 10.1002/mrm.1910380109
  4. Jordan Benedicte F., Baudelet Christine, Gallez Bernard, Carbon-centered radicals as oxygen sensors for in vivo electron paramagnetic resonance: screening for an optimal probe among commercially available charcoals, 10.1007/bf02592236
  5. Boyer S.J., Clarkson R.B., Electron paramagnetic resonance studies of an active carbon: The influence of preparation procedure on the oxygen response of the linewidth, 10.1016/0927-7757(93)02630-w
  6. Swartz Harold M, Clarkson Robert B, The measurement of oxygenin vivousing EPR techniques, 10.1088/0031-9155/43/7/017
  7. Goda, Cancer Res, 56, 3344 (1996)
  8. He G., Shankar R. A., Chzhan M., Samouilov A., Kuppusamy P., Zweier J. L., Noninvasive measurement of anatomic structure and intraluminal oxygenation in the gastrointestinal tract of living mice with spatial and spectral EPR imaging, 10.1073/pnas.96.8.4586
  9. Gallez Bernard, Jordan B�n�dicte F., Baudelet Christine, Misson Pierre-Damien, Pharmacological modifications of the partial pressure of oxygen in murine tumors: Evaluation using in vivo EPR oximetry, 10.1002/(sici)1522-2594(199910)42:4<627::aid-mrm2>3.0.co;2-m
  10. O'Hara Julia A., Goda Fuminori, Demidenko Eugene, Swartz Harold M., Effect on Regrowth Delay in a Murine Tumor of Scheduling Split-Dose Irradiation Based on Direct pO 2 Measurements by Electron Paramagnetic Resonance Oximetry, 10.2307/3579872
  11. Gallez Bernard, Jordan B�n�dicte F., Baudelet Christine, Microencapsulation of paramagnetic particles by pyrroxylin to preserve their responsiveness to oxygen when used as sensors for in vivo EPR oximetry, 10.1002/(sici)1522-2594(199907)42:1<193::aid-mrm25>3.0.co;2-c
  12. Packaging of paramagnetic materials in oximetry and other applications. In: editor. Biological magnetic resonance. 2000; 20, in press.
  13. Gallez Bernard, Mäder Karsten, Accurate and sensitive measurements of pO2 in vivo using low frequency EPR spectroscopy: how to confer biocompatibility to the oxygen sensors, 10.1016/s0891-5849(00)00405-6
  14. Gallez Bernard, Debuyst René, Dejehet Fernand, Liu Ke J., Walczak Tadeusz, Goda Fuminori, Demeure Roger, Taper Henryk, Swartz Harold M., Small particles of fusinite and carbohydrate chars coated with aqueous soluble polymers: Preparation and applications forin Vivo EPR oximetry, 10.1002/mrm.1910400120
  15. Gallez Bernard, Debuyst René, Liu Ke J., Demeure Roger, Dejehet Fernand, Swartz Harold M., Development of biocompatible implants of fusinite forin vivo EPR oximetry, 10.1007/bf01759782
  16. Clarkson R B, Odintsov B M, Ceroke P J, r-Larsen J H Ardenkjæ, Fruianu Michelina, Belford R L, Electron paramagnetic resonance and dynamic nuclear polarization of char suspensions: surface science and oximetry, 10.1088/0031-9155/43/7/012
  17. Swartz Harold M., Walczak Tadeusz, Developing in Vivo EPR Oximetry for Clinical use, Oxygen Transport to Tissue XX (1998) ISBN:9781461372066 p.243-252, 10.1007/978-1-4615-4863-8_29
Bibliographic reference Jia, He ; Beghein, Nelson ; Ceroke, P ; Clarkson, R B ; Swartz, H M ; et. al. Development of biocompatible oxygen-permeable films holding paramagnetic carbon particles: evaluation of their performance and stability in EPR oximetry.. In: Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine, Vol. 46, no. 3, p. 610-4 (2001)
Permanent URL http://hdl.handle.net/2078.1/8940