User menu

Accès à distance ? S'identifier sur le proxy UCLouvain

Immediate functional loading of single-tooth TiO2 grit-blasted implant restoration. A controlled prospective study in a porcine model. Part II: Histology and histomorphometry

  1. Attard Nikolai J., Zarb George A., Immediate and early implant loading protocols: A literature review of clinical studies, 10.1016/j.prosdent.2005.04.015
  2. Brunski JB, Int J Oral Maxillofac Implants, 15, 15 (2000)
  3. Duyck Joke, Naert Ignace, Ronold Hans Jacob, Ellingsen Jan Eirik, Van Oosterwyck Hans, Vander Sloten Jos, The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study, 10.1034/j.1600-0501.2001.012003207.x
  4. Kitamura Eriko, Stegaroiu Roxana, Nomura Shuichi, Miyakawa Osamu, Biomechanical aspects of marginal bone resorption around osseointegrated implants: considerations based on a three-dimensional finite element analysis, 10.1111/j.1600-0501.2004.01022.x
  5. Szmukler-Moncler S., Salama H., Reingewirtz Y., Dubruille J. H., Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature, 10.1002/(sici)1097-4636(199822)43:2<192::aid-jbm14>3.0.co;2-k
  6. Kim Hyo Jin, Chang Ik Tae, Heo Seong Joo, Koak Jai Young, Kim Seong Kyun, Jang Jun Hyeog, Effect of magnetic field on the fibronectin adsorption, cell attachment and proliferation on titanium surface : Effect of magnetic field on the fibronectin adsorption, 10.1111/j.1600-0501.2005.01164.x
  7. Gotfredsen Klaus, Nimb Lars, Hjorting-hansen Erik, Jensen Jorgen Steen, Holmen Anders, Histomorphometric and removal torque analysis for TiO2hyphen;blasted titanium implants. An experimental study on dogs., 10.1034/j.1600-0501.1992.030205.x
  8. Bousdras VA, Clin Implant Dent Rel Res, 9, 197 (2007)
  9. van der Lubbe H. B. M., Klein C. P. A. T., de Groot K., A Simple Method for Preparing Thin (10 μm) Histological Sections of Undecalcified Plastic Embedded Bone with Implants, 10.3109/10520298809107179
  10. De Smet Els, Jaecques Siegfried, Vandamme Katleen, Vander Sloten Jos, Naert Ignace, Positive effect of early loading on implant stability in the bi-cortical guinea-pig model : Implant stability in the bi-cortical guinea-pig model, 10.1111/j.1600-0501.2005.01156.x
  11. Vercaigne Suzy, Wolke Joop G. C., Naert Ignace, Jansen John A., A histological evaluation of TiO2-gritblasted and Ca-P magnetron sputter coated implants placed into the trabecular bone of the goat: part 2, 10.1034/j.1600-0501.2000.011004314.x
  12. Piattelli A., Corigliano M., Scarano A., Costigliola G., Paolantonio M., Immediate Loading of Titanium Plasma-Sprayed Implants: An Histologic Analysis in Monkeys, 10.1902/jop.1998.69.3.321
  13. Quinlan P, Int J Oral Maxillofac Implants, 20, 360 (2005)
  14. Meyer U, Int J Oral Maxillofac Implants, 18, 489 (2003)
  15. Nkenke Emeka, Lehner Bernhard, Weinzierl Konstanze, Thams Ulf, Neugebauer Jorg, Steveling Helmut, Radespiel-Troger Martin, Neukam Friedrich Wilhelm, Bone contact, growth, and density around immediately loaded implants in the mandible of mini pigs, 10.1034/j.1600-0501.2003.120906.x
  16. Berglundh T., Abrahamsson I., Lindhe J., Bone reactions to longstanding functional load at implants: an experimental study in dogs, 10.1111/j.1600-051x.2005.00747.x
  17. Lazzara RJ, Int J Periodontics Restor Dent, 26, 9 (2006)
  18. Lekholm U, Tissue integrated prosthesis: osseointegration in clinical dentistry, 199 (1985)
  19. Isidor Flemming, Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys., 10.1034/j.1600-0501.1996.070208.x
  20. Isidor Flemming, Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulation, 10.1111/j.1600-0501.1997.tb00001.x
  21. Sagara Masaaki, Akagawa Yasumasa, Nikai Hiromasa, Tsuru Hiromichi, The effects of early occlusal loading on one-stage titanium alloy implants in beagle dogs: A pilot study, 10.1016/0022-3913(93)90107-y
  22. Ko CC, J Dent Res, 82, 585 (2003)
  23. Heitz-Mayfield L. J., Schmid B., Weigel C., Gerber S., Bosshardt D. D., Jonsson J., Lang N. P., Jonsson J., Does excessive occlusal load affect osseointegration? An experimental study in the dog, 10.1111/j.1600-0501.2004.01019.x
  24. Bousdras VA, Int J Oral Maxillofac Surg, 35, 663 (2006)
  25. Ivanoff Carl-Johan, Widmark Goran, Hallgren Carin, Sennerby Lars, Wennerberg Ann, Histologic evaluation of the bone integration of TiO2 blasted and turned titanium microimplants in humans, 10.1034/j.1600-0501.2001.012002128.x
  26. Cochran D. L., Schenk R. K., Lussi A., Higginbottom F. L., Buser D., Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible, 10.1002/(sici)1097-4636(199804)40:1<1::aid-jbm1>3.0.co;2-q
  27. Quirynen Marc, Vogels Roel, Alsaadi Ghada, Naert Ignace, Jacobs Reinhilde, Steenberghe Daniel van, Predisposing conditions for retrograde peri-implantitis, and treatment suggestions : Retrograde peri-implantitis, 10.1111/j.1600-0501.2005.01147.x
  28. Bousdras VA, Int J Oral Maxillofac Implants, 21, 439 (2006)
  29. Samiotis A, Int Poster J Dent Oral Med, 7, 256 (2005)
  30. Testori T, Int J Oral Maxillofac Implants, 18, 544 (2003)
  31. Albrektsson T., J Prosthodont, 16, 29 (2003)
  32. Kenwright J, Clin Orthop, 241, 36 (1989)
  33. De Smet Els, Jaecques Siegfried V. N., Wevers Martine, Jansen John A., Jacobs Reinhilde, Sloten Jos Vander, Naert Ignace E., Effect of controlled early implant loading on bone healing and bone mass in guinea pigs, as assessed by micro-CT and histology, 10.1111/j.1600-0722.2006.00355.x
Bibliographic reference Bousdras, Vasilios A. ; Walboomers, Frank ; Jansen, John A. ; Cunningham, James L. ; Blunn, Gordon ; et. al. Immediate functional loading of single-tooth TiO2 grit-blasted implant restoration. A controlled prospective study in a porcine model. Part II: Histology and histomorphometry. In: Clinical Implant Dentistry and Related Research, Vol. 9, no. 4, p. 207-216 (2007)
Permanent URL http://hdl.handle.net/2078.1/37200