Experimental determination of the radial dose distribution in high gradient regions around Ir-192 wires : comparison of electron paramagnetic resonance imaging, films, and Monte Carlo simulations

  1. McJury M, Tapper P D, Cosgrove V P, Murphy P S, Griffin S, Leach M O, Webb S, Oldham M, Experimental 3D dosimetry around a high-dose-rate clinical192Ir source using a polyacrylamide gel (PAG) dosimeter, 10.1088/0031-9155/44/10/305
  2. Karaiskos P., Papagiannis P., Angelopoulos A., Sakelliou L., Baltas D., Sandilos P., Vlachos L., Dosimetry of 192Ir wires for LDR interstitial brachytherapy following the AAPM TG-43 dosimetric formalism, 10.1118/1.1339885
  3. Nath Ravinder, Amols Howard, Coffey Charles, Duggan Dennis, Jani Shirish, Li Zuofeng, Schell Michael, Soares Christopher, Whiting James, Cole Patricia E., Crocker Ian, Schwartz Robert, Intravascular brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 60, 10.1118/1.598496
  4. Nath Ravinder, Anderson Lowell L., Luxton Gary, Weaver Keith A., Williamson Jeffrey F., Meigooni Ali S., Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43, 10.1118/1.597458
  5. Ballester F., Hernández C., Pérez-Calatayud J., Lliso F., Monte Carlo calculation of dose rate distributions around Ir192 wires, 10.1118/1.598142
  6. Baltas D., Karaiskos P., Papagiannis P., Sakelliou L., Loeffler E., Zamboglou N., Beta versus gamma dosimetry close to Ir-192 brachytherapy sources, 10.1118/1.1395038
  7. Reynaert N, Eijkeren M Van, Taeymans Y, Thierens H, Dosimetry of192Ir sources used for endovascular brachytherapy, 10.1088/0031-9155/46/2/316
  8. Wang Ruqing, Li X. Allen, A Monte Carlo calculation of dosimetric parameters of 90Sr/90Y and 192Ir SS sources for intravascular brachytherapy, 10.1118/1.1319374
  9. Williamson Jeffrey F., Li Zuofeng, Monte Carlo aided dosimetry of the microselectron pulsed and high dose-rate 192 Ir sources, 10.1118/1.597483
  10. Anctil Jean-Claude, Clark Brenda G., Arsenault Clément J., Experimental determination of dosimetry functions of Ir-192 sources, 10.1118/1.598457
  11. Tolli H, Johansson K -A, Quality assurance in brachytherapy: the displacement effect in the vicinity of60Co and192Ir brachytherapy sources, 10.1088/0031-9155/38/10/009
  12. Valicenti R. K., Kirov A. S., Meigooni A. S., Mishra V., Das R. K., Williamson J. F., Experimental validation of Monte Carlo dose calculations about a high-intensity Ir-192 source for pulsed dose-rate brachytherapy, 10.1118/1.597484
  13. Chiu-Tsao Sou-Tung, Duckworth Tamara L., Patel Neil S., Pisch Julianna, Harrison Louis B., Verification of Ir-192 near source dosimetry using GAFCHROMIC®film, 10.1118/1.1637733
  14. Niroomand-Rad Azam, Blackwell Charles Robert, Coursey Bert M., Gall Kenneth P., Galvin James M., McLaughlin William L., Meigooni Ali S., Nath Ravinder, Rodgers James E., Soares Christopher G., Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55, 10.1118/1.598407
  15. Chiu-Tsao Sou-Tung, Medich David, Munro John, The use of new GAFCHROMIC® EBT film for I125 seed dosimetry in Solid Water® phantom : GAFCHROMIC® EBT film for I125 seed dosimetry, 10.1118/1.2955746
  16. Mehta Kishor, Girzikowsky Reinhard, Alanine-ESR dosimetry for radiotherapy IAEA experience, 10.1016/s0969-8043(96)00164-9
  17. Regulla D.F., Deffner U., Dosimetry by ESR spectroscopy of alanine, 10.1016/0020-708x(82)90238-1
  18. Hayes Robert B., Haskell Edwin H., Wieser Albrecht, Romanyukha Alexander A., Hardy Byron L., Barrus Jeffrey K., Assessment of an alanine EPR dosimetry technique with enhanced precision and accuracy, 10.1016/s0168-9002(99)00957-2
  19. Antonovic Laura, Gustafsson Håkan, Alm Carlsson Gudrun, Carlsson Tedgren Åsa, Evaluation of a lithium formate EPR dosimetry system for dose measurements around I192r brachytherapy sources : Lithium formate EPR dosimetry for I192r sources, 10.1118/1.3110068
  20. Gustafsson H., Olsson S., Lund A., Lund E., Ammonium Formate, a Compound for Sensitive EPR Dosimetry, 10.1667/rr3142
  21. Lund A, Olsson S, Bonora M, Lund E, Gustafsson H, New materials for ESR dosimetry, 10.1016/s1386-1425(01)00719-3
  22. Lund E., Gustafsson H., Danilczuk M., Sastry M.D., Lund A., Vestad T.A., Malinen E., Hole E.O., Sagstuen E., Formates and dithionates: sensitive EPR-dosimeter materials for radiation therapy, 10.1016/j.apradiso.2004.08.015
  23. Morita Yasuyuki, Ohno Keiichi, Ohashi Kazutoshi, Sohma Junkichi, ESR imaging investigation on depth profiles of radicals in organic solid dosimetry, 10.1016/0883-2889(89)90071-3
  24. Colacicchi S., Onori S., Petetti E., Sotgiu A., Application of low frequency EPR imaging to alanine dosimetry, 10.1016/0969-8043(93)90254-8
  25. Anton, Bruker Spin Report, 157-158, 48 (2006)
  26. Gustafsson Håkan, Kruczala Krzysztof, Lund Eva, Schlick Shulamith, Visualizing the Dose Distribution and Linear Energy Transfer by 1D and 2D ESR Imaging: A Potassium Dithionate Dosimeter Irradiated with C6+and N7+Ions, 10.1021/jp803695p
  27. Vanea Emilia S., Levêque Philippe, Abboud Fadi, Bol Anne, Denis Jean Marc, Kolbun Natallia, Vynckier Stefaan, Gallez Bernard, Evaluation of the dose distribution gradient in the close vicinity of brachytherapy seeds using electron paramagnetic resonance imaging, 10.1002/mrm.21947
  28. Kuppusamy Periannan, Chzhan Michael, Zweier Jay L., Principles of Imaging, In Vivo EPR (ESR) (2003) ISBN:9781461349068 p.99-152, 10.1007/978-1-4615-0061-2_6
  29. Cheung Y C, Yu Peter K N, Young E C M, Chan C L, Ng M F, Tang Francis, The dose distribution close to an wire source: EGS4 Monte Carlo calculations, 10.1088/0031-9155/42/2/011
  30. Cheung Y.C., Yu Peter K.N., Young E.C.M., Chan C.L., Ng M.F., Tang Francis N.F., Wong Tony P.Y., The electron-dose distribution surrounding an 192Ir wire brachytherapy source investigated using EGS4 simulations and GafChromicTM film, 10.1016/s0969-8043(96)00280-1
  31. Eaton, EPR Imaging and In Vivo EPR (1991)
  32. Fujii Hirotada, Berliner Lawrence J., One- and two-dimensional EPR imaging studies on Phantoms and Plant specimens, 10.1002/mrm.1910020310
  33. Ohno, J. Magn. Reson., 50, 145 (1982)
  34. Sotgiu A, Gazzillo D, Momo F, ESR imaging: spatial deconvolution in the presence of an asymmetric hyperfine structure, 10.1088/0022-3719/20/36/027
  35. McRobbie, MRI. From Picture to Proton (2003)
  36. Ahn Kang-Hyun, Halpern Howard J., Simulation of 4D spectral-spatial EPR images, 10.1016/j.jmr.2007.02.013
  37. Ahn Kang-Hyun, Halpern Howard J., Object dependent sweep width reduction with spectral–spatial EPR imaging, 10.1016/j.jmr.2007.01.021
  38. Ahn Kang-Hyun, Halpern Howard J., Spatially uniform sampling in 4-D EPR spectral-spatial imaging, 10.1016/j.jmr.2006.12.007
  39. Levêque Philippe, Godechal Quentin, Bol Anne, Trompier François, Gallez Bernard, X-band EPR imaging as a tool for gradient dose reconstruction in irradiated bones : EPRI for spatial dose distribution in irradiated bones, 10.1118/1.3194775
  40. Butson Martin J, Cheung Tsang, Yu Peter K.N., Weak energy dependence of EBT gafchromic film dose response in the 50kVp–10MVp X-ray range, 10.1016/j.apradiso.2005.07.002
  41. Hill R, Holloway L, Baldock C, A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams, 10.1088/0031-9155/50/21/n06
  42. Cheung Tsang, Butson Martin J, Yu Peter K N, Post-irradiation colouration of Gafchromic EBT radiochromic film, 10.1088/0031-9155/50/20/n04
  43. J. F. Briesmeister MCNP 2000
  44. Vestad Tor Arne, Malinen Eirik, Lund Anders, Hole Eli Olaug, Sagstuen Einar, EPR dosimetric properties of formates, 10.1016/s0969-8043(03)00165-9
  45. T. Grimbergen A. Aalbers B. Mijnheer J. Seuntjens H. Thierens J. Van Dam F. Wittkamper J. Zoetelief Dosimetry of low and medium energy x-rays: A code of practice for use in radiotherapy and radiobiology 1997
  46. Anton Mathias, Kapsch Ralf-Peter, Krystek Michael, Renner Franziska, Response of the alanine/ESR dosimetry system to MV x-rays relative to60Co radiation, 10.1088/0031-9155/53/10/020
  47. Bergstrand E.S., Bjerke H., Hole E.O., An experimental investigation of the electron energy dependence of the EPR alanine dosimetry system, 10.1016/j.radmeas.2004.05.010
  48. Bergstrand Eva Stabell, Shortt Ken R, Ross Carl K, Hole Eli Olaug, An investigation of the photon energy dependence of the EPR alanine dosimetry system, 10.1088/0031-9155/48/12/306
  49. Malinen Eirik, Waldeland Einar, Hole Eli Olaug, Sagstuen Einar, The energy dependence of lithium formate EPR dosimeters for clinical electron beams, 10.1088/0031-9155/52/14/022
  50. Zeng G G, McEwen M R, Rogers D W O, Klassen N V, An experimental and Monte Carlo investigation of the energy dependence of alanine/EPR dosimetry: II. Clinical electron beams, 10.1088/0031-9155/50/6/006
  51. Waldeland Einar, Hole Eli Olaug, Sagstuen Einar, Malinen Eirik, The energy dependence of lithium formate and alanine EPR dosimeters for medium energy x rays : Medium energy x-ray dependence of EPR dosimeters, 10.1118/1.3432567
  52. van der Laarse R., Granero D., Pérez-Calatayud J., Meigooni Ali. S., Ballester F., Dosimetric characterization of Ir-192 LDR elongated sources : Dosimetric characterization of Ir-192 elongated sources, 10.1118/1.2839102
  53. Deene Y De, Reynaert N, Wagter C De, On the accuracy of monomer/polymer gel dosimetry in the proximity of a high-dose-rate192Ir source, 10.1088/0031-9155/46/11/304
  54. Ishikawa M, Bengua G, Sutherland K L, Hiratsuka J, Katoh N, Shimizu S, Aoyama H, Fujita K, Yamazaki R, Horita K, Shirato H, A feasibility study of novel plastic scintillation dosimetry with pulse-counting mode, 10.1088/0031-9155/54/7/015
  55. Wai P., Adamovics J., Krstajic N., Ismail A., Nisbet A., Doran S., Dosimetry of the microSelectron-HDR Ir-192 source using PRESAGE™ and optical CT, 10.1016/j.apradiso.2008.06.038
  56. Toye W C, Das K R, Todd S P, Kenny M B, Franich R D, Johnston P N, An experimental MOSFET approach to characterize 192Ir HDR source anisotropy, 10.1088/0031-9155/52/17/015
Bibliographic reference Kolbun, Natallia ; Levêque, Philippe ; Abboud, Fadi ; Bol, Anne ; Vynckier, Stefaan ; et. al. Experimental determination of the radial dose distribution in high gradient regions around Ir-192 wires : comparison of electron paramagnetic resonance imaging, films, and Monte Carlo simulations. In: Medical Physics, Vol. 37, no. 10, p. 5448-5455 (2010)
Permanent URL http://hdl.handle.net/2078.1/34963