User menu

Accès à distance ? S'identifier sur le proxy UCLouvain

Evaluation and optimization of the extended information process unit (E-IPU) validation module integrating the sysmex flag systems and the recommendations of the French-speaking cellular hematology group (GFHC).

  1. Boursier Guilaine, Vukasovic Ines, Brguljan Pika Mesko, Lohmander Maria, Ghita Irina, Bernabeu Andreu Francisco A., Barrett Edward, Brugnoni Duilio, Kroupis Christos, Sprongl Ludek, Thelen Marc H.M., Vanstapel Florent, Vodnik Tatjana, Huisman Willem, Vaubourdolle Michel, on behalf of the Working Group Accr, Accreditation process in European countries – an EFLM survey, 10.1515/cclm-2015-0780
  2. Geneviève F, Feuillets De Biologie, LVI(317) (2014)
  3. Cornet E., Behier C., Troussard X., Guidance for storing blood samples in laboratories performing complete blood count with differential, 10.1111/j.1751-553x.2012.01452.x
  4. Palmer L., Briggs C., McFadden S., Zini G., Burthem J., Rozenberg G., Proytcheva M., Machin S. J., ICSH recommendations for the standardization of nomenclature and grading of peripheral blood cell morphological features, 10.1111/ijlh.12327
  5. Cornet E., Boubaya M., Troussard X., Contribution of the new XN-1000 parameters NEUT-RI and NEUT-WY for managing patients with immature granulocytes, 10.1111/ijlh.12372
  6. Eilertsen H., Hagve T.-A., Do the Flags Related to Immature Granulocytes Reported by the Sysmex XE-5000 Warrant a Microscopic Slide Review?, 10.1309/ajcp4v4exyffoell
  7. Hotton Julie, Broothaers Jan, Swaelens Caroline, Cantinieaux Brigitte, Performance and Abnormal Cell Flagging Comparisons of Three Automated Blood Cell Counters, 10.1309/ajcpe5r4soqbuulz
  8. Tefferi A, Thiele J, Vannucchi A M, Barbui T, An overview on CALR and CSF3R mutations and a proposal for revision of WHO diagnostic criteria for myeloproliferative neoplasms, 10.1038/leu.2014.35
  9. King M.-J., Garçon L., Hoyer J. D., Iolascon A., Picard V., Stewart G., Bianchi P., Lee S.-H., Zanella A., , ICSH guidelines for the laboratory diagnosis of nonimmune hereditary red cell membrane disorders, 10.1111/ijlh.12335
  10. Blood Cells: A Practical Guide, ISBN:9780470987551, 10.1002/9780470987551
  11. Mullier François, Lainey Elodie, Fenneteau Odile, Da Costa Lydie, Schillinger Françoise, Bailly Nicolas, Cornet Yvan, Chatelain Christian, Dogne Jean-Michel, Chatelain Bernard, Additional erythrocytic and reticulocytic parameters helpful for diagnosis of hereditary spherocytosis: results of a multicentre study, 10.1007/s00277-010-1138-3
  12. Tanaka Yuzo, Tanaka Yumiko, Gondo Kazumi, Maruki Yoshiko, Kondo Tamiaki, Asai Satomi, Matsushita Hiromichi, Miyachi Hayato, Performance Evaluation of Platelet Counting by Novel Fluorescent Dye Staining in the XN-Series Automated Hematology Analyzers : Platelet Counting by Fluorescent Dye Staining, 10.1002/jcla.21691
  13. Schoorl M., Schoorl M., Oomes J., van Pelt J., New Fluorescent Method (PLT-F) on Sysmex XN2000 Hematology Analyzer Achieved Higher Accuracy in Low Platelet Counting, 10.1309/ajcpuaggb4url5xo
  14. LE ROUX G., VLAD A., ECLACHE V., MALANQUIN C., COLLON J.-F., GANTIER M., SCHILLINGER F., PELTIER J.-Y., SAVIN B., LETESTU R., BARAN-MARSZAK F., FENAUX P., AJCHENBAUM-CYMBALISTA F., Routine diagnostic procedures of myelodysplastic syndromes: value of a structural blood cell parameter (NEUT-X) determined by the Sysmex XE-2100TM : ROUTINE DIAGNOSTIC PROCEDURES OF MYELODYSPLASTIC SYNDROMES, 10.1111/j.1751-553x.2010.01247.x
Bibliographic reference Cornet, Edouard ; Mullier, François ; Despas, Noemie ; Jacqmin, Hugues ; Geara, Carole ; et. al. Evaluation and optimization of the extended information process unit (E-IPU) validation module integrating the sysmex flag systems and the recommendations of the French-speaking cellular hematology group (GFHC).. In: Scandinavian Journal of Clinical & Laboratory Investigation, Vol. 76, no. 6, p. 465-471 (2016)
Permanent URL http://hdl.handle.net/2078.1/175094