User menu

Accès à distance ? S'identifier sur le proxy UCLouvain

Titanium niobium nitride knee implants are not inferior to chrome cobalt components for primary total knee arthroplasty

  1. Antonios D., Rousseau P., Larange A., Kerdine-Romer S., Pallardy M., Mechanisms of IL-12 Synthesis by Human Dendritic Cells Treated with the Chemical Sensitizer NiSO4, 10.4049/jimmunol.0901992
  2. Basko-Plluska JL, Thyssen JP, Schalock PC (2011) Cutaneous and systemic hypersensitivity reactions to metallic implants. Dermatitis 22:65–79
  3. Beecker J, Gordon J, Pratt M (2009) An interesting case of joint prosthesis allergy. Dermatitis 20:4–9
  4. Bergschmidt Philipp, Bader Rainer, Ganzer Dirk, Hauzeur Christian, Lohmann Christoph H., Krüger Alexander, Rüther Wolfgang, Tigani Domenico, Rani Nicola, Esteve José Luis, Prats Fernando Lopez, Zorzi Claudio, Madonna Vincenzo, Rigotti Stefano, Benazzo Francesco, Rossi Stefano Marco Paolo, Mittelmeier Wolfram, Prospective multi-centre study on a composite ceramic femoral component in total knee arthroplasty: Five-year clinical and radiological outcomes, 10.1016/j.knee.2015.02.003
  5. Bloemke AD, Clarke HD (2014) Prevalence of self-reported metal allergy in patients undergoing primary total knee arthroplasty. J Knee Surg. doi: 10.1055/s-0034-1381959
  6. Caicedo Marco S., Desai Ronak, McAllister Kyron, Reddy Anand, Jacobs Joshua J., Hallab Nadim J., Soluble and particulate Co-Cr-Mo alloy implant metals activate the inflammasome danger signaling pathway in human macrophages: A novel mechanism for implant debris reactivity, 10.1002/jor.20826
  7. Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12
  8. Ezzet Kace A, Hermida Juan C, Colwell Clifford W, D???Lima Darryl D, Oxidized Zirconium Femoral Components Reduce Polyethylene Wear in a Knee Wear Simulator : , 10.1097/01.blo.0000148576.70780.13
  9. Frigerio Elena, Pigatto Paolo D., Guzzi Gianpaolo, Altomare Gianfranco, Metal sensitivity in patients with orthopaedic implants: a prospective study, 10.1111/j.1600-0536.2011.01886.x
  10. Gao X, He RX, Yan SG, Wu LD (2011) Dermatitis associated with chromium following total knee arthroplasty. J Arthroplasty 26:665
  11. Granchi D., Cenni E., Giunti A., Baldini N., Metal hypersensitivity testing in patients undergoing joint replacement: A systematic review, 10.1302/0301-620x.94b8.28135
  12. Grosu Irina, Lavand’homme Patricia, Thienpont Emmanuel, Pain after knee arthroplasty: an unresolved issue, 10.1007/s00167-013-2750-2
  13. Lovász G., Park S. H., Ebramzadeh E., Benya P. D., Llinás A., Bellyei Á., Luck Jr J. V., Sarmiento A., Characteristics of degeneration in an unstable knee with a coronal surface step-off, 10.1302/0301-620x.83b3.9674
  14. Hallab NJ, Caicedo M, Epstein R, McAllister K, Jacobs JJ (2010) In vitro reactivity to implant metals demonstrates a person-dependant association with both T-cell and B-cell activation. J Biomed Mat Res 92:667–682
  15. Innocenti Massimo, Civinini Roberto, Carulli Christian, Matassi Fabrizio, Villano Marco, The 5-year Results of an Oxidized Zirconium Femoral Component for TKA, 10.1007/s11999-009-1109-y
  16. Innocenti Massimo, Carulli Christian, Matassi Fabrizio, Carossino Anna Maria, Brandi Maria Luisa, Civinini Roberto, Total knee arthroplasty in patients with hypersensitivity to metals, 10.1007/s00264-013-2229-2
  17. Kim Y.-H., Park J.-W., Kim J.-S., Comparison of the Genesis II total knee replacement with oxidised zirconium and cobalt-chromium femoral components in the same patients: A prospective, double-blind, randomised controlled study, 10.1302/0301-620x.94b9.28854
  18. Kitagawa Atsushi, Chin Takaaki, Tsumura Nobuhiro, Iguchi Tetsushiro, Metal sensitivity in patients before and after total knee arthroplasty (TKA): comparison between ceramic surfaced oxidized zirconium and cobalt-chromium implants, 10.7243/2052-594x-1-3
  19. Lützner Jörg, Dinnebier Gerd, Hartmann Albrecht, Günther Klaus-Peter, Kirschner Stephan, Study rationale and protocol: prospective randomized comparison of metal ion concentrations in the patient's plasma after implantation of coated and uncoated total knee prostheses, 10.1186/1471-2474-10-128
  20. Luetzner J, Krummenauer F, Lengel AM, Ziegler J, Witzleb WC (2007) Serum metal ion exposure after total knee arthroplasty. Clin Orthop Relat Res 461:136–142
  21. Magone Kevin, Luckenbill Daniel, Goswami Tarun, Metal ions as inflammatory initiators of osteolysis, 10.1007/s00402-015-2196-8
  22. Münch Henrik J, Jacobsen Stig S, Olesen Jens T, Menné Torkil, Søballe Kjeld, Johansen Jeanne D, Thyssen Jacob P, The association between metal allergy, total knee arthroplasty, and revision : Study based on the Danish Knee Arthroplasty Register, 10.3109/17453674.2014.999614
  23. Mohammed A, Metcalfe A, Woodnutt D (2014) Medium-term outcome of titanium nitride, mobile bearing total knee replacement. Acta Orthop Belg 80:269–275
  24. Park Se-Wook, Kim Hyungsuk, In Yong, Fracture of titanium nitride-coated femoral component after total knee arthroplasty, 10.1016/j.knee.2014.04.002
  25. Post Zachary D., Orozco Fabio R., Ong Alvin C., Metal Sensitivity After TKA Presenting With Systemic Dermatitis and Hair Loss, 10.3928/01477447-20130327-35
  26. Razak A, Ebinesan AD, Charalambous CP (2013) Metal allergy screening prior to joint arthroplasty and its influence on implant choice: a Delphi consensus study amongst orthopaedic arthroplasty surgeons. Knee Surg Relat Res. doi: 10.5792/ksrr.2013.25.4.186
  27. Seil Romain, Pape Dietrich, Causes of failure and etiology of painful primary total knee arthroplasty, 10.1007/s00167-011-1631-9
  28. Thienpont Emmanuel, Berger Yorick, No allergic reaction after TKA in a chrome-cobalt-nickel-sensitive patient: case report and review of the literature, 10.1007/s00167-012-2000-z
  29. Thienpont Emmanuel, Opsomer Gaetan, Koninckx Angelique, Houssiau Frederic, Joint Awareness in Different Types of Knee Arthroplasty Evaluated With the Forgotten Joint Score, 10.1016/j.arth.2013.04.024
  30. Thomsen Marc, Rozak Matthias, Thomas Peter, Pain in a chromium-allergic patient with total knee arthroplasty: disappearance of symptoms after revision with a special surface-coated TKA ­— a case report, 10.3109/17453674.2011.579521
  31. Thyssen Jacob P., Menné Torkil, Metal Allergy—A Review on Exposures, Penetration, Genetics, Prevalence, and Clinical Implications, 10.1021/tx9002726
  32. Breugem Stefan J. M., van Ooij Bas, Haverkamp Daniël, Sierevelt Inger N., van Dijk C. Niek, No difference in anterior knee pain between a fixed and a mobile posterior stabilized total knee arthroplasty after 7.9 years, 10.1007/s00167-012-2281-2
  33. Vaninbroukx Michaël, Labey Luc, Innocenti Bernardo, Bellemans Johan, Cementing the femoral component in total knee arthroplasty: Which technique is the best?, 10.1016/j.knee.2008.11.015
  34. Van Opstal N, Verheyden F (2011) Revision of a tibial baseplate using a customized oxinium component in a case of suspected metal allergy: a case report. Acta Orthop Belg 77:691–695
  35. Verma Shyam B., Mody Bharat, Gawkrodger David J., Dermatitis on the knee following knee replacement: a minority of cases show contact allergy to chromate, cobalt or nickel but a causal association is unproven, 10.1111/j.0105-1873.2006.0775o.x
Bibliographic reference Thienpont, Emmanuel. Titanium niobium nitride knee implants are not inferior to chrome cobalt components for primary total knee arthroplasty. In: Archives of Orthopaedic and Trauma Surgery, Vol. 135, no.12, p. 1749-1754 (2015)
Permanent URL http://hdl.handle.net/2078.1/172236