User menu

Accès à distance ? S'identifier sur le proxy UCLouvain

Low-dose multidetector computed tomography of the cervical spine: Optimization of iterative reconstruction strength levels

  1. Munera Felipe, Rivas Luis A., Nunez Diego B., Quencer Robert M., Imaging Evaluation of Adult Spinal Injuries: Emphasis on Multidetector CT in Cervical Spine Trauma, 10.1148/radiol.12110526
  2. Van Goethem Johan W. M., Maes Menno, Özsarlak Özkan, van den Hauwe Luc, Parizel Paul M., Imaging in spinal trauma, 10.1007/s00330-004-2625-5
  3. Douglas-Akinwande Annette C., Rydberg Jonas, Shah Mitesh V., Phillips Michael D., Caldemeyer Karen S., Lurito Joseph T., Ying Jun, Mathews Vincent P., Accuracy of Contrast-Enhanced MDCT and MRI for Identifying the Severity and Cause of Neural Foraminal Stenosis in Cervical Radiculopathy: A Prospective Study, 10.2214/ajr.09.2988
  4. Freund Michael, Sartor Klaus, Degenerative spine disorders in the context of clinical findings, 10.1016/j.ejrad.2005.12.005
  5. Tins Bernhard, Technical aspects of CT imaging of the spine, 10.1007/s13244-010-0047-2
  6. Biswas Debdut, Bible Jesse E, Bohan Michael, Simpson Andrew K, Whang Peter G, Grauer Jonathan N, Radiation Exposure from Musculoskeletal Computerized Tomographic Scans : , 10.2106/jbjs.h.01199
  7. Lee Ting-Yim, Chhem Rethy K., Impact of new technologies on dose reduction in CT, 10.1016/j.ejrad.2010.06.036
  8. Fleischmann Dominik, Boas F. Edward, Computed tomography—old ideas and new technology, 10.1007/s00330-011-2056-z
  9. Willemink Martin J., de Jong Pim A., Leiner Tim, de Heer Linda M., Nievelstein Rutger A. J., Budde Ricardo P. J., Schilham Arnold M. R., Iterative reconstruction techniques for computed tomography Part 1: Technical principles, 10.1007/s00330-012-2765-y
  10. Gervaise Alban, Osemont Benoît, Lecocq Sophie, Noel Alain, Micard Emilien, Felblinger Jacques, Blum Alain, CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT, 10.1007/s00330-011-2271-7
  11. Becce Fabio, Ben Salah Yosr, Verdun Francis R., Vande Berg Bruno C., Lecouvet Frederic E., Meuli Reto, Omoumi Patrick, Computed tomography of the cervical spine: comparison of image quality between a standard-dose and a low-dose protocol using filtered back-projection and iterative reconstruction, 10.1007/s00256-013-1576-9
  12. Silva Alvin C., Lawder Holly J., Hara Amy, Kujak Jennifer, Pavlicek William, Innovations in CT Dose Reduction Strategy: Application of the Adaptive Statistical Iterative Reconstruction Algorithm, 10.2214/ajr.09.2953
  13. Moscariello Antonio, Takx Richard A. P., Schoepf U. Joseph, Renker Matthias, Zwerner Peter L., O’Brien Terrence X., Allmendinger Thomas, Vogt Sebastian, Schmidt Bernhard, Savino Giancarlo, Fink Christian, Bonomo Lorenzo, Henzler Thomas, Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique—comparison with traditional filtered back projection, 10.1007/s00330-011-2164-9
  14. Winklehner Anna, Karlo Christoph, Puippe Gilbert, Schmidt Bernhard, Flohr Thomas, Goetti Robert, Pfammatter Thomas, Frauenfelder Thomas, Alkadhi Hatem, Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential, 10.1007/s00330-011-2227-y
  15. Deak Paul D., Smal Yulia, Kalender Willi A., Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product, 10.1148/radiol.10100047
  16. Willemink Martin J., Leiner Tim, de Jong Pim A., de Heer Linda M., Nievelstein Rutger A. J., Schilham Arnold M. R., Budde Ricardo P. J., Iterative reconstruction techniques for computed tomography part 2: initial results in dose reduction and image quality, 10.1007/s00330-012-2764-z
  17. Miéville Frédéric A., Gudinchet François, Brunelle Francis, Bochud François O., Verdun Francis R., Iterative reconstruction methods in two different MDCT scanners: Physical metrics and 4-alternative forced-choice detectability experiments – A phantom approach, 10.1016/j.ejmp.2011.12.004
  18. Singh Sarabjeet, Kalra Mannudeep K., Gilman Matthew D., Hsieh Jiang, Pien Homer H., Digumarthy Subba R., Shepard Jo-Anne O., Adaptive Statistical Iterative Reconstruction Technique for Radiation Dose Reduction in Chest CT: A Pilot Study, 10.1148/radiol.11101450
  19. Miéville Frédéric A., Gudinchet François, Rizzo Elena, Ou Phalla, Brunelle Francis, Bochud François O., Verdun Francis R., Paediatric cardiac CT examinations: impact of the iterative reconstruction method ASIR on image quality – preliminary findings, 10.1007/s00247-011-2146-8
  20. Rampado O., Bossi L., Garabello D., Davini O., Ropolo R., Characterization of a computed tomography iterative reconstruction algorithm by image quality evaluations with an anthropomorphic phantom, 10.1016/j.ejrad.2012.06.017
  21. Rapalino O., Kamalian S., Kamalian S., Payabvash S., Souza L. C. S., Zhang D., Mukta J., Sahani D. V., Lev M. H., Pomerantz S. R., Cranial CT with Adaptive Statistical Iterative Reconstruction: Improved Image Quality with Concomitant Radiation Dose Reduction, 10.3174/ajnr.a2826
  22. Mulkens T.H., Marchal P., Daineffe S., Salgado R., Bellinck P., Rijdt B. t., Kegelaers B., Termote J.-L., Comparison of Low-Dose With Standard-Dose Multidetector CT in Cervical Spine Trauma, 10.3174/ajnr.a0608
  23. Weidemann J., Stamm G., Galanski M., Keberle M., Comparison of the image quality of various fixed and dose modulated protocols for soft tissue neck CT on a GE Lightspeed scanner, 10.1016/j.ejrad.2007.11.027
  24. Gnannt R., Winklehner A., Goetti R., Schmidt B., Kollias S., Alkadhi H., Low Kilovoltage CT of the Neck with 70 kVp: Comparison with a Standard Protocol, 10.3174/ajnr.a2910
  25. Hoang Jenny K., Yoshizumi Terry T., Nguyen Giao, Toncheva Greta, Choudhury Kingshuk Roy, Gafton Andreia R., Eastwood James D., Lowry Carolyn, Hurwitz Lynne M., Variation in Tube Voltage for Adult Neck MDCT: Effect on Radiation Dose and Image Quality, 10.2214/ajr.11.6831
  26. von Falck Christian, Hartung Alexander, Berndzen Frank, King Benjamin, Galanski Michael, Shin Hoen-oh, Optimization of Low-Contrast Detectability in Thin-Collimated Modern Multidetector CT Using an Interactive Sliding-Thin-Slab Averaging Algorithm : , 10.1097/rli.0b013e3181614f2d
  27. von Falck Christian, Galanski Michael, Shin Hoen-oh, Informatics in Radiology: Sliding-Thin-Slab Averaging for Improved Depiction of Low-Contrast Lesions with Radiation Dose Savings at Thin-Section CT, 10.1148/rg.302096007
Bibliographic reference Omoumi, Patrick ; Verdun, Francis R ; Ben Salah, Yosr ; Vande Berg, Bruno ; Lecouvet, Frédéric ; et. al. Low-dose multidetector computed tomography of the cervical spine: Optimization of iterative reconstruction strength levels. In: Acta radiologica (1987- ), Vol. 55, no. 3, p. 335-344 (2014)
Permanent URL http://hdl.handle.net/2078.1/164162