Lühr, Armin
Hansen, David C.
Sobolevsky, Nikolai
Palmans, Hugo
Rossomme, Séverine
[UCL]
Bassler, Niels
Background. In radiation therapy, the principal dosimetric quantity of interest is the absorbed dose to water. Therefore, a dose conversion to dose to water is required for dose deposited by ion beams in other media. This is in particular necessary for dose measurements in plastic phantoms for increased positioning accuracy, graphite calorimetry being developed as a primary standard for dose to water dosimetry, but also for the comparison of dose distributions from Monte Carlo simulations with those of pencil beam algorithms. Material and methods. In the conversion of absorbed dose to phantom material to absorbed dose to water the water-to-material stopping power ratios (STPR) and the fluence correction factors (FCF) for the full charged particle spectra are needed. We determined STPR as well as FCF for water to graphite, bone (compact), and PMMA as a function of water equivalent depth, zw, with the Monte Carlo code SHIELD-HIT10A. Simulations considering all secondary ions were performed for primary protons as well as carbon, nitrogen and oxygen ions with a total range of 3 cm, 14.5 cm and 27 cm as well as for two spread-out Bragg-peaks (SOBP). STPR as a function of depth are also compared to a recently proposed analytical formula. Results. The STPR are of the order of 1.022, 1.070, and 1.112 for PMMA, bone, and graphite, respectively. STPR vary only little with depth except close to the total range of the ion and they can be accurately approximated with an analytical formula. The amplitude of the FCF depends on the non-elastic nuclear interactions and it is unity if these interactions are turned off in the simulation. Fluence corrections are of the order of a percent becoming more pronounced for larger depths resulting in dose difference of the order of 5% around 25 cm. The same order of magnitude is observed for SOBP. Conclusions. We conclude that for ions with small total range (zw-eq ≤3 cm) dosimetry without applying FCF could in principle be performed in phantoms of materials other than water without a significant loss of accuracy. However, in clinical high-energy ion beams with penetration depths zw-eq ≥3 cm, where accurate positioning in water is not an issue, absorbed dose measurements should be directly performed in water or accurate values of FCF need to be established. © 2011 Informa Healthcare.
- Palmans Hugo, Thomas Russell, Simon Mary, Duane Simon, Kacperek Andrzej, DuSautoy Alan, Verhaegen Frank, A small-body portable graphite calorimeter for dosimetry in low-energy clinical proton beams, 10.1088/0031-9155/49/16/019
- Sakama Makoto, Kanai Tatsuaki, Fukumura Akifumi, Abe Kyoko, Evaluation ofwvalues for carbon beams in air, using a graphite calorimeter, 10.1088/0031-9155/54/5/002
- Rosenschöld Per Munck Af, Aznar Marianne C., Nygaard Ditte E., Persson Gitte F., Korreman Stine S., Engelholm Svend Aage, Nyström Håkan, A treatment planning study of the potential of geometrical tracking for intensity modulated proton therapy of lung cancer, 10.3109/0284186x.2010.500620
- Paganetti Harald, Dose to water versus dose to medium in proton beam therapy, 10.1088/0031-9155/54/14/004
- Palmans H, Proceedings International Symposium on Standards, Applications and Quality Assurance in Medical Radiation Dosimetry IAEA-CN-182/277 (2011)
- Palmans Hugo, Symons Julyan E, Denis Jean-Marc, Kock Evan A de, Jones Dan T L, Vynckier Stefaan, Fluence correction factors in plastic phantoms for clinical proton beams, 10.1088/0031-9155/47/17/302
- Palmans Hugo, Verhaegen Frank, Assigning nonelastic nuclear interaction cross sections to Hounsfield units for Monte Carlo treatment planning of proton beams, 10.1088/0031-9155/50/5/021
- Lühr Armin, Hansen David C, Jäkel Oliver, Sobolevsky Nikolai, Bassler Niels, Analytical expressions for water-to-air stopping-power ratios relevant for accurate dosimetry in particle therapy, 10.1088/0031-9155/56/8/012
- Gudowska Irena, Sobolevsky Nikolai, Andreo Pedro, Belki D evad, Brahme Anders, Ion beam transport in tissue-like media using the Monte Carlo code SHIELD-HIT, 10.1088/0031-9155/49/10/008
- Hansen DC, Int J Rad Biol (2011)
- ICRU Report 49, Stopping powers and ranges for protons and alpha particles (1993)
- Krämer M, Jäkel O, Haberer T, Kraft G, Schardt D, Weber U, Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization, 10.1088/0031-9155/45/11/313
- Weber Uli, Kraft Gerhard, Design and construction of a ripple filter for a smoothed depth dose distribution in conformal particle therapy, 10.1088/0031-9155/44/11/306
- Scholz M., Kraft G., Track structure and the calculation of biological effects of heavy charged particles, 10.1016/0273-1177(95)00784-c
- Janni Joseph F., Energy loss, range, path length, time-of-flight, straggling, multiple scattering, and nuclear interaction probability, 10.1016/0092-640x(82)90004-3
- ICRU Report 63, Nuclear data for neutron and proton radiotherapy and for radiation protection (2000)
- Hartnack C., Puri Rajeev K., Aichelin J., Konopka J., Bass S.A., Stöcker H., Greiner W., Modelling the many-body dynamics of heavy ion collisions: Present status and future perspective, 10.1007/s100500050045
- Bassler Niels, Holzscheiter Michael H., Petersen Jørgen B., Neutron Fluence in Antiproton Radiotherapy, Measurements and Simulations, 10.3109/0284186x.2010.501812
- Schmitz Tobias, Blaickner Matthias, Schütz Christian, Wiehl Norbert, Kratz Jens V., Bassler Niels, Holzscheiter Michael H., Palmans Hugo, Sharpe Peter, Otto Gerd, Hampel Gabriele, Dose calculation in biological samples in a mixed neutron-gamma field at the TRIGA reactor of the University of Mainz, 10.3109/0284186x.2010.500306
- Medin Joakim, Andreo Pedro, Monte Carlo calculated stopping-power ratios, water/air, for clinical proton dosimetry (50 - 250 MeV), 10.1088/0031-9155/42/1/006
Bibliographic reference |
Lühr, Armin ; Hansen, David C. ; Sobolevsky, Nikolai ; Palmans, Hugo ; Rossomme, Séverine ; et. al. Fluence correction factors and stopping power ratios for clinical ion beams. In: Acta Oncologica, Vol. 50, no. 6, p. 797-805 (2011) |
Permanent URL |
http://hdl.handle.net/2078.1/163515 |