Jacquet, Luc-Marie
[UCL]
Dion, R.
Noirhomme, Philippe
[UCL]
Van Dijck, M
Goenen, Martin
[UCL]
The wearable version of the Novacor left ventricular assist system has been implanted in a 44-year-old man as a bridge to retransplantation. Apart from a temporary right ventricular failure, the postoperative course was smooth and the patient underwent retransplantation after 95 days of support. Expected complications like infection or bleeding could be avoided or minimized.
Bibliographic reference |
Jacquet, Luc-Marie ; Dion, R. ; Noirhomme, Philippe ; Van Dijck, M ; Goenen, Martin. Successful bridge to retransplantation with the wearable Novacor left ventricular assist system.. In: The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation, Vol. 15, no. 6, p. 620-2 (1996) |
Permanent URL |
http://hdl.handle.net/2078.1/13252 |