Aubriet, Frédéric
Poleunis, Claude
[UCL]
Muller, Jean-François
Bertrand, Patrick
[UCL]
Most of the first-row transition-metal oxides, M(A)O(B) (M = Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn) were examined by static secondary ion mass spectrometry (s-SIMS) and laser ablation/ionization Fourier transform ion cyclotron resonance mass spectrometry (LA-FTICRMS). Positive and negative ions show strong correlation between the studied oxide and the detected cluster ions. Specific M(x)O(y) (+/-) species were systematically observed with both MS techniques for each investigated M(A)O(B) transition-metal oxide. Moreover, the ion composition and ion distribution are greatly dependent on the ionization technique. Laser ablation (LA)/ionization leads to larger cluster ions (ionic species with nearly hundred atoms were in particular detected for Sc2O3 and Y2O3 oxides), whereas hydrogenated, dihydrogenated, and sometimes trihydrogenated species were observed in s-SIMS. However, the ion distribution for a given M(x)O(y) (+/-) ion series (i.e. ions including the same number of metal atoms M) generally presented important similarities in both techniques.Finally, it was demonstrated that the chemical state of metal atoms in the observed ionic species is closely dependent on the metal electronic valence shell. High valence states (+III, +IV, +V, and +VI) are favored for metals with a less-than-half full valence shell configuration, whereas for other first-row transition metals (manganese, iron, cobalt, nickel, copper and zinc) lower metal valence states (0, +I or, +II) are involved.
- Van Stipdonk, J. Mass Spectrom., 34, 677 (1999)
- Van Stipdonk, Int. J. Mass Spectrom., 203, 59 (2000)
- Benninghoven, Phys. Lett. A, 40, 169 (1972)
- Benninghoven, Surf. Sci., 39, 416 (1973)
- Weng, Appl. Surf. Sci., 99, 185 (1996)
- De Smet, J. Chem. Soc., Faraday Trans., 94, 941 (1998)
- , , . ToF-SIMS Study of Pr6O11MoO3 Mixtures: Effects of the Ultrasonic Treatment During the Preparation, Proceedings of the 11th International Conference on Secondary Ion Mass Spectrometry, Orlando, Florida, 7–12 September 1997, Wiley New York, 1998; 655.
- De Smet, Chem. Mater., 11, 324 (1999)
- . A TOF-SIMS Study of the Iron-Antimony Mixed Oxide Catalyst System. Proceedings of the 12th International Conference on Secondary Ion Mass Spectrometry, Brussels, Belgium, 5–11 September 1999, Elsevier, 2000; 875.
- Groenewold, Int. J. Mass Spectrom., 178, 19 (1998)
- Van Ham, Nucl. Instr. and Meth. B, 161–163, 245 (2000)
- . ToF-SIMS Measurements of the Oxidation State of Transition Metals. Proceedings of the 11th International Conference on Secondary Ion Mass Spectrometry, Orlando, Florida, 7–12 September 1997, Wiley New York, 1998; 943.
- Cuynen, Rapid Commun. Mass Spectrom., 130, 2287 (1999)
- , . The Static SIMS Library, Part 1. Surface spectra: Manchester, UK, 1999.
- Michiels, Spectrochim. Acta B, 38, 1347 (1983)
- Michiels, Anal. Chem., 56, 1115 (1984)
- Gibson, J. Appl. Phys., 78, 1274 (1995)
- Chaoui, Analusis, 24, 146 (1996)
- Dance, J. Chem. Soc., Dalton Trans., 15, 2557 (1997)
- Hachimi, Int. J. Mass Spectrom. Ion Processes, 144, 23 (1995)
- Poels, Anal. Chem., 70, 504 (1998)
- Maunit, Rapid Commun. Mass Spectrom., 9, 225 (1995)
- Maunit, Int. J. Mass Spectrom. Ion Processes, 156, 173 (1996)
- Thierry de Ville d'Avray, Eur. J. Mass. Spectrom., 4, 441 (1998)
- Struyf, Rapid Commun. Mass Spectrom., 10, 551 (1996)
- Struyf, J. Am. Soc. Mass Spectrom., 9, 482 (1998)
- Van Vaeck, Spectrochim. Acta B, Atomic Spectroscopy., 53, 367 (1998)
- Oliveira M.C, Marçalo J, Vieira M.C, Ferreiraac M.A.Almoster, Formation of some transition metal oxide cluster anions and reactivity towards methanol in the gas phase, 10.1016/s1387-3806(98)14199-4
- , . Static Tof-Sims and Fourier Transform Laser Microprobe Mass Spectrometry for Molecular Information On Inorganic Coatings On Aluminium, Proceedings of the 12th International Conference on Secondary Ion Mass Spectrometry, Brussels, Belgium, 5–11 September 1999, Elsevier 2000; 1033.
- , Laser Microprobe FTICRMS as a Tool for Inorganic Speciation Studies. An Understanding of Cluster Ions Formation, Proceedings of the 47th ASMS Conference on Mass Spectrometry and Allied Topics, Dallas, Texas, 13–17 June 1999.
- Allen, Anal. Chem., 68, 4052 (1996)
- Mass spectrometric identification of inorganic substances by laser microprobe mass analysis. Microbeam Analysis. San Francisco Press: San Franscisco, 1985; 305.
- Colin, Appl. Surf. Sci., 125, 29 (1997)
- Lobstein, Appl. Surf. Sci., 89, 307 (1995)
- Cossarutto, Appl. Surf. Sci., 126, 352 (1998)
- Chaoui, Chem. Mater., 10, 3888 (1998)
- Giardini Guidoni, Appl. Surf. Sci., 154/155, 467 (2000)
- Lafargue, J. Mass Spectrom., 31, 623 (1996)
- Lafargue, Chem. Phys. Lett., 288, 494 (1998)
- Aubriet, Int. J. Mass Spectrom., 209, 5 (2001)
- Aubriet, J. Mass Spectrom., 36, 641 (2001)
- , . Laser ablation and secondary ion mass spectrometry of inorganic compounds. Part II: Elements for the understanding of ion formation in the study of transition metal oxides. Submitted for publication in Journal of Mass Spectrometry (Part II of the present series).
- , , , . A new generation of microprobe: Laser ionization and FT/ICR mass spectrometry. In Microbeam Analysis-1989, (ed). San Francisco Press: San Francisco, 1989; 311.
- Aubriet, Int. J. Mass Spectrom., 219, 717 (2002)
- Aubriet, Rapid Commun. Mass Spectrom., 11, 1596 (1997)
- Etude par spectrométrie de masse de la formation des agrégats ionisés induits par ablation/ionisation laser de composés minéraux: Application à la différenciation des degrés d'oxydation du chrome, Ph D. Thesis of the University of Metz (France), 1999.
- Ding, Chem. Phys. Lett., 331, 163 (2000)
- Mele, Int. J. Mass Spectrom. Ion Processes, 95, 359 (1990)
- Gibson, J. Phys. Chem., 98, 11321 (1994)
- Ma, Progr. Nat. Sci., 6, 159 (1996)
- Gold, Int. J. Mass Spectrom. Ion Processes, 102, 115 (1990)
- Aubriet, Appl. Surf. Sci., 186, 315 (2002)
- Bucker, J. Chem. Phys., 88, 3678 (1988)
- Aubriet, Int. J. Mass Spectrom., 198, 189 (2000)
- Aubriet, Int. J. Mass Spectrom., 198, 213 (2000)
- Wenthold, J. Chem. Phys., 106, 9961 (1997)
- Rudnyi, J. Chem. Thermodyn., 21, 247 (1989)
- Kubler B., Millon E., Gaumet J. J., Muller J. F., Formation of High Mass Cnclusters (n > 100) by Laser Ablation/Desorption Coupled with Mass Spectrometry, 10.1080/10641229608001177
- Hopwood, J. Phys. Chem. B, 101, 10704 (1997)
- Fisher Keith, Willett Gary, Fullerene Research at the University of New South Wales, 10.1080/10641229909350303
- Van Heijnsbergen, Phys. Rev. Lett., 83, 4983 (1999)
- Zhang, Chem. Phys. Lett., 274, 115 (1997)
- Ingolfsson, Chem. Phys. Lett., 360, 415 (2002)
- Negishi, Chem. Phys. Lett., 364, 127 (2002)
- Foltin, J. Chem. Phys., 114, 8971 (2001)
- Plog, Surf. Sci., 67, 565 (1977)
- Kaiser, J. Chem. Phys., 110, 1437 (1999)
- Albaret, Appl. Surf. Sci., 144/145, 672 (1999)
- Albaret, J. Chem. Phys., 113, 2238 (2000)
- Etude théorique d'interface metal-oxyde et d'agrégats d'oxyde de titane non-stoechiometriques, Ph D. Thesis, University of Jussieu Paris VI, Paris, France, 2000.
- Liu Xiang-Hong, Zhang Xiao-Guang, Wang Xiu-Yan, Lou Nan-Quan, Formation of Ca-O clusters and their protonation and hydration in direct laser vaporization, 10.1002/bbpc.19971010714
- Jackson, Chem. Phys., 262, 179 (2000)
- Bruynseels, Anal. Chem., 56, 871 (1984)
- Aubriet, J. Phys. Chem. A, 106, 6053 (2002)
- Chertihin, J. Phys. Chem. A, 101, 5090 (1997)
- Bell, J. Phys. Chem. A, 102, 1733 (1998)
- Foltin, J. Chem. Phys., 111, 9577 (1999)
- Zhang, J. Am. Soc. Mass Spectrom., 14, 42 (2003)
- Liu, Int. J. Mass Spectrom., 177, l1 (1998)
- , . Secondary Ion Mass Spectrometry. John Wiley & Sons: New York, 1987.
- Van Stipdonk, Int. J. Mass Spectrom., 202, 111 (2000)
- , . Formation of Halide Cluster Ions and Assessment of their Stability. Proceedings of the 47th ASMS Conference on Mass Spectrometry and Allied Topics, Dallas, Texas, 13–17 June, 1999.
Bibliographic reference |
Aubriet, Frédéric ; Poleunis, Claude ; Muller, Jean-François ; Bertrand, Patrick. Laser ablation and secondary ion mass spectrometry of inorganic transition-metal compounds. Part I: comparison between static ToF-SIMS and LA-FTICRMS.. In: Journal of mass spectrometry : JMS, Vol. 41, no. 4, p. 527-42 (2006) |
Permanent URL |
http://hdl.handle.net/2078.1/10517 |